无线运动传感器节点系统的设计与实现

Gang-song Dong, C. Li
{"title":"无线运动传感器节点系统的设计与实现","authors":"Gang-song Dong, C. Li","doi":"10.1109/ICARCE55724.2022.10046588","DOIUrl":null,"url":null,"abstract":"Smart wearable devices have emerged in response to the situation, providing a new method for people's health monitoring. Three kinds of intelligent sensors have been selected to adopt the modular optimization design idea, and the wireless motion sensor node system and data display interface have been designed, which can collect and record heart rate, body temperature, movement steps and other information in real time and effectively. Based on ADS1292 analog front-end chip design ECG detection circuit, through the difference threshold method to improve detection accuracy, complete real-time collection and recording of user's heart rate, achieve dynamic ECG test and display, analysis and calculation of user's heart rate, the error is not more than 5%. Push-pull LMT70 temperature sensor is used to measure the body temperature, which increases the carrying capacity and keeps the sampling rate no less than 10 times/min. Three high-resolution ADXL355 acceleration sensors are added, and the interval sampling method is adopted to calculate the number of moving steps and moving distance, and the error is kept less than 5%. At the same time, the wireless motion sensor node has the function of surfing the Internet and transmitting data to the server to complete the data operation. After debugging and analysis for many times, the system has reached the design requirements, and has the advantages of low cost, high precision, easy to use and low power consumption.","PeriodicalId":416305,"journal":{"name":"2022 International Conference on Automation, Robotics and Computer Engineering (ICARCE)","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and Implementation of Wireless Motion Sensor Node System\",\"authors\":\"Gang-song Dong, C. Li\",\"doi\":\"10.1109/ICARCE55724.2022.10046588\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Smart wearable devices have emerged in response to the situation, providing a new method for people's health monitoring. Three kinds of intelligent sensors have been selected to adopt the modular optimization design idea, and the wireless motion sensor node system and data display interface have been designed, which can collect and record heart rate, body temperature, movement steps and other information in real time and effectively. Based on ADS1292 analog front-end chip design ECG detection circuit, through the difference threshold method to improve detection accuracy, complete real-time collection and recording of user's heart rate, achieve dynamic ECG test and display, analysis and calculation of user's heart rate, the error is not more than 5%. Push-pull LMT70 temperature sensor is used to measure the body temperature, which increases the carrying capacity and keeps the sampling rate no less than 10 times/min. Three high-resolution ADXL355 acceleration sensors are added, and the interval sampling method is adopted to calculate the number of moving steps and moving distance, and the error is kept less than 5%. At the same time, the wireless motion sensor node has the function of surfing the Internet and transmitting data to the server to complete the data operation. After debugging and analysis for many times, the system has reached the design requirements, and has the advantages of low cost, high precision, easy to use and low power consumption.\",\"PeriodicalId\":416305,\"journal\":{\"name\":\"2022 International Conference on Automation, Robotics and Computer Engineering (ICARCE)\",\"volume\":\"5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 International Conference on Automation, Robotics and Computer Engineering (ICARCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICARCE55724.2022.10046588\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 International Conference on Automation, Robotics and Computer Engineering (ICARCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICARCE55724.2022.10046588","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

智能可穿戴设备应运而生,为人们的健康监测提供了一种新的方法。选择了三种智能传感器,采用模块化优化设计思路,设计了无线运动传感器节点系统和数据显示界面,可以实时有效地采集和记录心率、体温、运动步数等信息。基于ADS1292模拟前端芯片设计心电检测电路,通过差值法提高检测精度,完成对用户心率的实时采集和记录,实现动态心电测试和显示,分析计算用户心率,误差不超过5%。采用推挽式LMT70温度传感器测量体温,增加了承载能力,采样率不低于10次/min。增加3个高分辨率ADXL355加速度传感器,采用间隔采样法计算移动步数和移动距离,误差保持在5%以内。同时,无线运动传感器节点具有上网和向服务器传输数据的功能,完成数据操作。经过多次调试和分析,该系统达到了设计要求,并且具有成本低、精度高、使用方便、功耗低等优点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Design and Implementation of Wireless Motion Sensor Node System
Smart wearable devices have emerged in response to the situation, providing a new method for people's health monitoring. Three kinds of intelligent sensors have been selected to adopt the modular optimization design idea, and the wireless motion sensor node system and data display interface have been designed, which can collect and record heart rate, body temperature, movement steps and other information in real time and effectively. Based on ADS1292 analog front-end chip design ECG detection circuit, through the difference threshold method to improve detection accuracy, complete real-time collection and recording of user's heart rate, achieve dynamic ECG test and display, analysis and calculation of user's heart rate, the error is not more than 5%. Push-pull LMT70 temperature sensor is used to measure the body temperature, which increases the carrying capacity and keeps the sampling rate no less than 10 times/min. Three high-resolution ADXL355 acceleration sensors are added, and the interval sampling method is adopted to calculate the number of moving steps and moving distance, and the error is kept less than 5%. At the same time, the wireless motion sensor node has the function of surfing the Internet and transmitting data to the server to complete the data operation. After debugging and analysis for many times, the system has reached the design requirements, and has the advantages of low cost, high precision, easy to use and low power consumption.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design and Implementation of MobileRobot Navigation System Based on ROS Platform Cooperative Pursuit in a Non-closed Bounded Domain 3D Reconstruction of Astronomical Site Selection Based on Multi-Source Remote Sensing Design and Implementation of Manipulator Based on Arduino Dynamic Reversible Data Hiding for Edge Contrast Enhancement of Medical Image
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1