一种新型SPECT小动物成像仪的设计

Donald W. Wilson, H. Barrett, L. Furenlid
{"title":"一种新型SPECT小动物成像仪的设计","authors":"Donald W. Wilson, H. Barrett, L. Furenlid","doi":"10.1109/NSSMIC.2001.1008697","DOIUrl":null,"url":null,"abstract":"We demonstrate, using computer models, the feasibility of a new SPECT system for imaging small animals such as mice. This system consists of four modular scintillation cameras, four multiple-pinhole apertures, electronics, and tomographic reconstruction software. All of these constituents have been designed in our laboratory. The cameras are 120 mm/spl times/120 mm with a resolution of approximately 2 mm, the apertures can have either single or multiple pinholes, and reconstruction is performed using the OS-EM algorithm. One major advantage of this system is the design flexibility it offers, as the cameras are easy to move and the apertures are simple to modify. We explored a number of possible configurations. One promising configuration had the four camera faces forming four sides of a cube with multiple-pinhole apertures employed to focus the incoming high-energy photons. This system is rotated three times, so that data are collected from a total of sixteen camera angles. It is shown that this hybrid system has some superior properties to single-aperture-type systems. We conclude that this proposed system offers advantages over current imaging systems in terms of flexibility, simplicity, and performance.","PeriodicalId":159123,"journal":{"name":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"A new design for a SPECT small-animal imager\",\"authors\":\"Donald W. Wilson, H. Barrett, L. Furenlid\",\"doi\":\"10.1109/NSSMIC.2001.1008697\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We demonstrate, using computer models, the feasibility of a new SPECT system for imaging small animals such as mice. This system consists of four modular scintillation cameras, four multiple-pinhole apertures, electronics, and tomographic reconstruction software. All of these constituents have been designed in our laboratory. The cameras are 120 mm/spl times/120 mm with a resolution of approximately 2 mm, the apertures can have either single or multiple pinholes, and reconstruction is performed using the OS-EM algorithm. One major advantage of this system is the design flexibility it offers, as the cameras are easy to move and the apertures are simple to modify. We explored a number of possible configurations. One promising configuration had the four camera faces forming four sides of a cube with multiple-pinhole apertures employed to focus the incoming high-energy photons. This system is rotated three times, so that data are collected from a total of sixteen camera angles. It is shown that this hybrid system has some superior properties to single-aperture-type systems. We conclude that this proposed system offers advantages over current imaging systems in terms of flexibility, simplicity, and performance.\",\"PeriodicalId\":159123,\"journal\":{\"name\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2001.1008697\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2001.1008697","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

我们利用计算机模型证明了一种新的SPECT系统对小动物(如小鼠)成像的可行性。该系统由四个模块化闪烁相机、四个多针孔孔径、电子设备和层析成像重建软件组成。所有这些成分都是在我们的实验室设计出来的。相机尺寸为120mm /spl倍/ 120mm,分辨率约为2mm,孔径可以有单个或多个针孔,使用OS-EM算法进行重建。这个系统的一个主要优点是它提供的设计灵活性,因为相机很容易移动,光圈很容易修改。我们探索了许多可能的配置。一种很有希望的配置是,四个相机面形成一个立方体的四个侧面,上面有多个针孔,用来聚焦入射的高能光子。这个系统旋转了三次,因此从总共16个摄像机角度收集数据。结果表明,该混合系统具有比单孔系统更优越的性能。我们得出的结论是,该系统在灵活性、简单性和性能方面优于当前的成像系统。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A new design for a SPECT small-animal imager
We demonstrate, using computer models, the feasibility of a new SPECT system for imaging small animals such as mice. This system consists of four modular scintillation cameras, four multiple-pinhole apertures, electronics, and tomographic reconstruction software. All of these constituents have been designed in our laboratory. The cameras are 120 mm/spl times/120 mm with a resolution of approximately 2 mm, the apertures can have either single or multiple pinholes, and reconstruction is performed using the OS-EM algorithm. One major advantage of this system is the design flexibility it offers, as the cameras are easy to move and the apertures are simple to modify. We explored a number of possible configurations. One promising configuration had the four camera faces forming four sides of a cube with multiple-pinhole apertures employed to focus the incoming high-energy photons. This system is rotated three times, so that data are collected from a total of sixteen camera angles. It is shown that this hybrid system has some superior properties to single-aperture-type systems. We conclude that this proposed system offers advantages over current imaging systems in terms of flexibility, simplicity, and performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Comparison of IEC and IEEE standards for computer-based control systems important to safety Helicity-correlated systematics for SLAC Experiment E158 Achievements of the ASTRO-E Hard X-ray Detector development Inexpensive position sensitive detector block for 40 mm diameter PMT using quadrant sharing configuration A /sup 252/Cf neutron irradiator for testing electronic components for the Large Hadron Collider
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1