互联水热发电系统的自动发电控制

K. S. Parmar, S. Majhi, D. Kothari
{"title":"互联水热发电系统的自动发电控制","authors":"K. S. Parmar, S. Majhi, D. Kothari","doi":"10.1109/INDCON.2010.5712663","DOIUrl":null,"url":null,"abstract":"This paper deals with automatic generation control of an interconnected hydrothermal system considering reheat type turbine in thermal plant area and low head turbine in hydro plant area using optimal controllers. The dynamical response of the load frequency control problem in an interconnected power system under consideration is improved with a practical viewpoint by designing the optimal output feedback controller. The optimal control methods are proposed and their dynamic responses are compared. The optimal control is determined by minimizing a performance index under the proposed output feedback conditions. The results indicate that the controllers exhibit better performance. In fact, the control systems designed on these methods satisfy the load frequency control requirements with a reasonable dynamic response.","PeriodicalId":109071,"journal":{"name":"2010 Annual IEEE India Conference (INDICON)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"48","resultStr":"{\"title\":\"Automatic generation control of an interconnected hydrothermal power system\",\"authors\":\"K. S. Parmar, S. Majhi, D. Kothari\",\"doi\":\"10.1109/INDCON.2010.5712663\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with automatic generation control of an interconnected hydrothermal system considering reheat type turbine in thermal plant area and low head turbine in hydro plant area using optimal controllers. The dynamical response of the load frequency control problem in an interconnected power system under consideration is improved with a practical viewpoint by designing the optimal output feedback controller. The optimal control methods are proposed and their dynamic responses are compared. The optimal control is determined by minimizing a performance index under the proposed output feedback conditions. The results indicate that the controllers exhibit better performance. In fact, the control systems designed on these methods satisfy the load frequency control requirements with a reasonable dynamic response.\",\"PeriodicalId\":109071,\"journal\":{\"name\":\"2010 Annual IEEE India Conference (INDICON)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"48\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 Annual IEEE India Conference (INDICON)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/INDCON.2010.5712663\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 Annual IEEE India Conference (INDICON)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/INDCON.2010.5712663","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 48

摘要

本文研究了考虑热电厂再热式水轮机和水电厂低水头水轮机的互联水热系统的自动发电控制问题。通过设计最优输出反馈控制器,从实用的角度改进了电网负荷频率控制问题的动态响应。提出了最优控制方法,并对其动态响应进行了比较。在给定的输出反馈条件下,通过最小化性能指标来确定最优控制。结果表明,该控制器具有较好的控制性能。实际上,根据这些方法设计的控制系统能够满足负载频率控制的要求,并具有合理的动态响应。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Automatic generation control of an interconnected hydrothermal power system
This paper deals with automatic generation control of an interconnected hydrothermal system considering reheat type turbine in thermal plant area and low head turbine in hydro plant area using optimal controllers. The dynamical response of the load frequency control problem in an interconnected power system under consideration is improved with a practical viewpoint by designing the optimal output feedback controller. The optimal control methods are proposed and their dynamic responses are compared. The optimal control is determined by minimizing a performance index under the proposed output feedback conditions. The results indicate that the controllers exhibit better performance. In fact, the control systems designed on these methods satisfy the load frequency control requirements with a reasonable dynamic response.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An efficient technique for protein classification using feature extraction by artificial neural networks Coordinated design of excitation and TCSC-based stabilizers for multimachine power system Estimation of the resonant frequency and magnetic polarizability of an edge coupled circular split ring resonator with rotated outer ring Realization of ultra wideband bandpass filter using new type of split-ring Defected Ground Structure Double-Pole Four-Throw RF CMOS switch design with double-gate transistors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1