减少桥墩局部冲刷牺牲桩直径和距离的评价

J. Gamboa, Valeria Quintanilla, E. Guzman, S. Santos
{"title":"减少桥墩局部冲刷牺牲桩直径和距离的评价","authors":"J. Gamboa, Valeria Quintanilla, E. Guzman, S. Santos","doi":"10.18178/ijscer.10.3.113-118","DOIUrl":null,"url":null,"abstract":"In this research, it was analyzed influence of variation of sacrificial piles diameter, as well as the distance between front pile and the face of the pier in reducing local scour depth. For this purpose, it was calibrated a physical test of an isolated cylindrical pier developed in a previous research. For calibration, numerical models were made with Manning's roughness coefficients of the sand of 0.023, 0.024 and 0.025 and the application of Froechlich and Colorado State University (CSU) equations to calculate the local scour depth. After that, 12 numerical models were made with the addition of sacrificial piles in a 30° triangular configuration to the calibrated model. The diameters of sacrificial piles were 5, 6, 7.5 and 10 mm and distances between front pile and the face pier were 75, 90 and 105 mm. According to the results, the highest percentage of local scour reduction was obtained when the sacrificial piles had a diameter of 10 mm and the distance between the front pile and the pier was equal to 105 mm. In this sense, when the distance between the front pile and the face pier was greater, the percentage of local scour reduction was higher. Also, based on the results, it is concluded that, Froechlich's equations and CSU lose precision when there are sacrificial piles.","PeriodicalId":101411,"journal":{"name":"International journal of structural and civil engineering research","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Evaluation of Diameter and Distance of Sacrificial Piles from the Bridge Pier in Reducing Local Scour\",\"authors\":\"J. Gamboa, Valeria Quintanilla, E. Guzman, S. Santos\",\"doi\":\"10.18178/ijscer.10.3.113-118\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this research, it was analyzed influence of variation of sacrificial piles diameter, as well as the distance between front pile and the face of the pier in reducing local scour depth. For this purpose, it was calibrated a physical test of an isolated cylindrical pier developed in a previous research. For calibration, numerical models were made with Manning's roughness coefficients of the sand of 0.023, 0.024 and 0.025 and the application of Froechlich and Colorado State University (CSU) equations to calculate the local scour depth. After that, 12 numerical models were made with the addition of sacrificial piles in a 30° triangular configuration to the calibrated model. The diameters of sacrificial piles were 5, 6, 7.5 and 10 mm and distances between front pile and the face pier were 75, 90 and 105 mm. According to the results, the highest percentage of local scour reduction was obtained when the sacrificial piles had a diameter of 10 mm and the distance between the front pile and the pier was equal to 105 mm. In this sense, when the distance between the front pile and the face pier was greater, the percentage of local scour reduction was higher. Also, based on the results, it is concluded that, Froechlich's equations and CSU lose precision when there are sacrificial piles.\",\"PeriodicalId\":101411,\"journal\":{\"name\":\"International journal of structural and civil engineering research\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of structural and civil engineering research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18178/ijscer.10.3.113-118\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of structural and civil engineering research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18178/ijscer.10.3.113-118","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究分析了牺牲桩直径的变化以及前桩与桥面距离对减小局部冲刷深度的影响。为此,对先前研究中开发的孤立圆柱墩进行了物理测试。为了进行标定,采用砂的Manning粗糙度系数分别为0.023、0.024和0.025,并应用Froechlich方程和Colorado State University (CSU)方程计算局部冲刷深度,建立数值模型。然后,在校正后的模型上加入30°三角形牺牲桩,建立了12个数值模型。牺牲桩直径分别为5、6、7.5和10 mm,前桩与面墩距离分别为75、90和105 mm。结果表明,当牺牲桩直径为10 mm,前桩与桥墩距离为105 mm时,局部减冲率最高。从这个意义上说,当前桩与面墩之间的距离越大时,局部冲刷减少的百分比越高。同时,在有牺牲桩存在的情况下,Froechlich方程和CSU方程失去了精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Diameter and Distance of Sacrificial Piles from the Bridge Pier in Reducing Local Scour
In this research, it was analyzed influence of variation of sacrificial piles diameter, as well as the distance between front pile and the face of the pier in reducing local scour depth. For this purpose, it was calibrated a physical test of an isolated cylindrical pier developed in a previous research. For calibration, numerical models were made with Manning's roughness coefficients of the sand of 0.023, 0.024 and 0.025 and the application of Froechlich and Colorado State University (CSU) equations to calculate the local scour depth. After that, 12 numerical models were made with the addition of sacrificial piles in a 30° triangular configuration to the calibrated model. The diameters of sacrificial piles were 5, 6, 7.5 and 10 mm and distances between front pile and the face pier were 75, 90 and 105 mm. According to the results, the highest percentage of local scour reduction was obtained when the sacrificial piles had a diameter of 10 mm and the distance between the front pile and the pier was equal to 105 mm. In this sense, when the distance between the front pile and the face pier was greater, the percentage of local scour reduction was higher. Also, based on the results, it is concluded that, Froechlich's equations and CSU lose precision when there are sacrificial piles.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Energy Efficiency: Use of BIM in Energy Analysis for Multi-family Residences Rainfall Runoff and Flood Simulations for Hurricane Impacts on Woonasquatucket River, USA. An Experimental and Numerical Study of the Load Distribution Effect on Composite Slab Shear Resistance Linear and Nonlinear Buckling Analysis of Castellated Beams Natural Volcanic Pozzolan-and Granulated Blast Furnace Slag-Based Alkali-Activated Repair Mortar
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1