一种带并网逆变器的孤岛微电网故障检测方案

S. F. Zarei, M. A. Ghasemi, S. Peyghami, F. Blaabjerg
{"title":"一种带并网逆变器的孤岛微电网故障检测方案","authors":"S. F. Zarei, M. A. Ghasemi, S. Peyghami, F. Blaabjerg","doi":"10.1109/eGRID52793.2021.9662140","DOIUrl":null,"url":null,"abstract":"This paper proposes a fault detection scheme for microgrids with grid-forming inverters. In this paper, a superimposed phase-current scheme with a voltage-restraint element is proposed which identifies the faults in an islanded microgrid with grid-forming inverters. In the proposed method, different factors including the implemented fault-ride-through strategy, the fault current limiting scheme, and the control structure of the grid-forming inverter are considered. Furthermore, the moving window concept is included, which considerably increases the detection speed. The severity and type of short circuit fault do not affect the functionality of the proposed method, and both symmetrical/asymmetrical short circuit faults are properly identified by the proposed scheme. Finally, the performance of the proposed scheme is demonstrated by applying different symmetrical/asymmetrical faults in a test system.","PeriodicalId":198321,"journal":{"name":"2021 6th IEEE Workshop on the Electronic Grid (eGRID)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Fault Detection Scheme for Islanded-Microgrid with Grid-Forming Inverters\",\"authors\":\"S. F. Zarei, M. A. Ghasemi, S. Peyghami, F. Blaabjerg\",\"doi\":\"10.1109/eGRID52793.2021.9662140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a fault detection scheme for microgrids with grid-forming inverters. In this paper, a superimposed phase-current scheme with a voltage-restraint element is proposed which identifies the faults in an islanded microgrid with grid-forming inverters. In the proposed method, different factors including the implemented fault-ride-through strategy, the fault current limiting scheme, and the control structure of the grid-forming inverter are considered. Furthermore, the moving window concept is included, which considerably increases the detection speed. The severity and type of short circuit fault do not affect the functionality of the proposed method, and both symmetrical/asymmetrical short circuit faults are properly identified by the proposed scheme. Finally, the performance of the proposed scheme is demonstrated by applying different symmetrical/asymmetrical faults in a test system.\",\"PeriodicalId\":198321,\"journal\":{\"name\":\"2021 6th IEEE Workshop on the Electronic Grid (eGRID)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-11-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 6th IEEE Workshop on the Electronic Grid (eGRID)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/eGRID52793.2021.9662140\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 6th IEEE Workshop on the Electronic Grid (eGRID)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/eGRID52793.2021.9662140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文提出了一种具有并网逆变器的微电网故障检测方案。本文提出了一种带电压约束元件的相电流叠加方案,用于海岛型逆变器微电网的故障识别。在该方法中,考虑了实现故障穿越策略、故障限流方案和成网逆变器控制结构等不同因素。此外,还引入了移动窗口的概念,大大提高了检测速度。短路故障的严重程度和类型不影响所提出方法的功能,并且所提出的方案可以正确识别对称/不对称短路故障。最后,通过在测试系统中应用不同的对称/不对称故障,验证了所提方案的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Fault Detection Scheme for Islanded-Microgrid with Grid-Forming Inverters
This paper proposes a fault detection scheme for microgrids with grid-forming inverters. In this paper, a superimposed phase-current scheme with a voltage-restraint element is proposed which identifies the faults in an islanded microgrid with grid-forming inverters. In the proposed method, different factors including the implemented fault-ride-through strategy, the fault current limiting scheme, and the control structure of the grid-forming inverter are considered. Furthermore, the moving window concept is included, which considerably increases the detection speed. The severity and type of short circuit fault do not affect the functionality of the proposed method, and both symmetrical/asymmetrical short circuit faults are properly identified by the proposed scheme. Finally, the performance of the proposed scheme is demonstrated by applying different symmetrical/asymmetrical faults in a test system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
3SSC Inverter Applied to a Photovoltaic System A Power Conversion System For Large-Scale Reversible SOFC Energy Storage System Impact of Grid Forming Power Converters on the Provision of Grid Services through VSC-HVdc Systems Flexible Power Point Tracking for Active Power Regulation in String-Inverter PV Plants with Power Optimizers A Modular Scalable SiC-based Flexible-Combined Heat and Power System Interface Converter with Small Capacitor and Advanced Grid-Support Functions
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1