{"title":"监控业务电缆的钢笔导体,以确保使用智能分割表粘接","authors":"David Scheepers, J. Beukes","doi":"10.1109/ROBOMECH.2019.8704704","DOIUrl":null,"url":null,"abstract":"This paper investigates a method for monitoring the service cable PEN conductor on a smart grid to provide information regarding deteriorating infrastructure. The consequences of leaving a deteriorated or broken service cable PEN conductor is examined for the TN-C-S earthing scheme using smart split meters. The feasibility of implementing a monitoring method is evaluated through system modelling and simulation as well as implementation on a physical setup. Simulation and experimental results indicated that it would indeed be able to approximate the service cable PEN conductor value but require more investigation regarding the behaviour of the incidental earthing impedance.","PeriodicalId":344332,"journal":{"name":"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","volume":"28 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitoring of the service cable PEN conductor to assure bonding using a smart split meter\",\"authors\":\"David Scheepers, J. Beukes\",\"doi\":\"10.1109/ROBOMECH.2019.8704704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper investigates a method for monitoring the service cable PEN conductor on a smart grid to provide information regarding deteriorating infrastructure. The consequences of leaving a deteriorated or broken service cable PEN conductor is examined for the TN-C-S earthing scheme using smart split meters. The feasibility of implementing a monitoring method is evaluated through system modelling and simulation as well as implementation on a physical setup. Simulation and experimental results indicated that it would indeed be able to approximate the service cable PEN conductor value but require more investigation regarding the behaviour of the incidental earthing impedance.\",\"PeriodicalId\":344332,\"journal\":{\"name\":\"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)\",\"volume\":\"28 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ROBOMECH.2019.8704704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 Southern African Universities Power Engineering Conference/Robotics and Mechatronics/Pattern Recognition Association of South Africa (SAUPEC/RobMech/PRASA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ROBOMECH.2019.8704704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Monitoring of the service cable PEN conductor to assure bonding using a smart split meter
This paper investigates a method for monitoring the service cable PEN conductor on a smart grid to provide information regarding deteriorating infrastructure. The consequences of leaving a deteriorated or broken service cable PEN conductor is examined for the TN-C-S earthing scheme using smart split meters. The feasibility of implementing a monitoring method is evaluated through system modelling and simulation as well as implementation on a physical setup. Simulation and experimental results indicated that it would indeed be able to approximate the service cable PEN conductor value but require more investigation regarding the behaviour of the incidental earthing impedance.