8通道相控阵颈动脉磁共振成像在3T

C. Luo, Xiaoqing Hu, X. Chen, Lei Zhang, Shengping Liu, Xin Liu, Hairong Zheng, Ye Li
{"title":"8通道相控阵颈动脉磁共振成像在3T","authors":"C. Luo, Xiaoqing Hu, X. Chen, Lei Zhang, Shengping Liu, Xin Liu, Hairong Zheng, Ye Li","doi":"10.1109/APMC.2015.7413391","DOIUrl":null,"url":null,"abstract":"In order to obtain high resolution image of vessel wall of carotid artery, an 8-channel carotid coil is fabricated for 3T magnetic resonance imaging in this study. The phantom experiments and in-vivo studies are implemented in order to validate the performance of the fabricated 8-channel carotid coil. The high resolution images are obtained with the fabricated 8-channel carotid coil in clinical examination for in vivo experiment, showing its potential for the clinical diagnosis.","PeriodicalId":269888,"journal":{"name":"2015 Asia-Pacific Microwave Conference (APMC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An 8-channel phased array for carotid artery magnetic resonance imaging at 3T\",\"authors\":\"C. Luo, Xiaoqing Hu, X. Chen, Lei Zhang, Shengping Liu, Xin Liu, Hairong Zheng, Ye Li\",\"doi\":\"10.1109/APMC.2015.7413391\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to obtain high resolution image of vessel wall of carotid artery, an 8-channel carotid coil is fabricated for 3T magnetic resonance imaging in this study. The phantom experiments and in-vivo studies are implemented in order to validate the performance of the fabricated 8-channel carotid coil. The high resolution images are obtained with the fabricated 8-channel carotid coil in clinical examination for in vivo experiment, showing its potential for the clinical diagnosis.\",\"PeriodicalId\":269888,\"journal\":{\"name\":\"2015 Asia-Pacific Microwave Conference (APMC)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 Asia-Pacific Microwave Conference (APMC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APMC.2015.7413391\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 Asia-Pacific Microwave Conference (APMC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APMC.2015.7413391","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了获得颈动脉血管壁的高分辨率图像,本研究制作了一个8通道颈动脉线圈,用于3T磁共振成像。为了验证制备的8通道颈动脉线圈的性能,进行了模拟实验和体内研究。将制作的8通道颈动脉线圈用于临床检查,获得高分辨率的图像,进行体内实验,显示其在临床诊断中的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An 8-channel phased array for carotid artery magnetic resonance imaging at 3T
In order to obtain high resolution image of vessel wall of carotid artery, an 8-channel carotid coil is fabricated for 3T magnetic resonance imaging in this study. The phantom experiments and in-vivo studies are implemented in order to validate the performance of the fabricated 8-channel carotid coil. The high resolution images are obtained with the fabricated 8-channel carotid coil in clinical examination for in vivo experiment, showing its potential for the clinical diagnosis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Silicon based THz dielectric waveguides Generation of radio orbital angular momentum (OAM) waves with circular metallic waveguide Characterization and modeling of large signal dynamics of GaN HEMTs Attempt of the metallic 3D printing technology for millimeter-wave antenna implementations Radiation pattern reconfigurable antenna using double layer tunable graphene superstrate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1