Aquasift:一种低成本的手持式恒电位器,用于饮用水中污染物的电化学检测

Philip Wu, Gabriela Vázquez, Nicholas Mikstas, S. Krishnan, U. Kim
{"title":"Aquasift:一种低成本的手持式恒电位器,用于饮用水中污染物的电化学检测","authors":"Philip Wu, Gabriela Vázquez, Nicholas Mikstas, S. Krishnan, U. Kim","doi":"10.1109/GHTC.2017.8239306","DOIUrl":null,"url":null,"abstract":"The difficulty of detecting small quantities of contaminants in water supplies currently threatens the health of millions of people worldwide, as consumption of contaminated water has been associated with both cancerous and noncancerous health risks. Existing technologies make it possible to very accurately quantify contaminant levels in water; however the expense, extensive training, and off-site analysis required by these methods prevent wide scale use. Electrochemical detection offers many advantages, such as portability, minimal use of instrumentation, and ready integration with electronics. With a goal of water quality interventions, we have presented an affordable and point-of-use platform capable of detecting small amounts of arsenic in water samples. Our electrochemical system utilizes a three-electrode sensor integrated with a handheld, self-designed potentiostat called Aquasift. Aquasift's hardware is simplified as much as possible to maintain affordability and relies on firmware complexity to provide functionality comparable to more expensive bench top potentiostats. Several optional on-board digital filters are available for signal conditioning. The Aquasift can sample at a rate up to 1KSPS and the output data rate is adjustable from 1KSPS down to 1 sample per second. The board uses 12-bit data converters to provide a voltage resolution of 806 micro volts. The Aquasift is powered directly from the USB port and requires no additional power source. We compare the results obtained from the Aquasift of arsenic testing to those obtained from a commercially available bench top potentiostat. The results show Aquasift's comparable accuracy to the commercial analyzer, and demonstrate that our proposed system is a more affordable, portable alternative to laboratory testing.","PeriodicalId":248924,"journal":{"name":"2017 IEEE Global Humanitarian Technology Conference (GHTC)","volume":"4 18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Aquasift: A low-cost, hand-held potentiostat for point-of-use electrochemical detection of contaminants in drinking water\",\"authors\":\"Philip Wu, Gabriela Vázquez, Nicholas Mikstas, S. Krishnan, U. Kim\",\"doi\":\"10.1109/GHTC.2017.8239306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The difficulty of detecting small quantities of contaminants in water supplies currently threatens the health of millions of people worldwide, as consumption of contaminated water has been associated with both cancerous and noncancerous health risks. Existing technologies make it possible to very accurately quantify contaminant levels in water; however the expense, extensive training, and off-site analysis required by these methods prevent wide scale use. Electrochemical detection offers many advantages, such as portability, minimal use of instrumentation, and ready integration with electronics. With a goal of water quality interventions, we have presented an affordable and point-of-use platform capable of detecting small amounts of arsenic in water samples. Our electrochemical system utilizes a three-electrode sensor integrated with a handheld, self-designed potentiostat called Aquasift. Aquasift's hardware is simplified as much as possible to maintain affordability and relies on firmware complexity to provide functionality comparable to more expensive bench top potentiostats. Several optional on-board digital filters are available for signal conditioning. The Aquasift can sample at a rate up to 1KSPS and the output data rate is adjustable from 1KSPS down to 1 sample per second. The board uses 12-bit data converters to provide a voltage resolution of 806 micro volts. The Aquasift is powered directly from the USB port and requires no additional power source. We compare the results obtained from the Aquasift of arsenic testing to those obtained from a commercially available bench top potentiostat. The results show Aquasift's comparable accuracy to the commercial analyzer, and demonstrate that our proposed system is a more affordable, portable alternative to laboratory testing.\",\"PeriodicalId\":248924,\"journal\":{\"name\":\"2017 IEEE Global Humanitarian Technology Conference (GHTC)\",\"volume\":\"4 18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Global Humanitarian Technology Conference (GHTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/GHTC.2017.8239306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Global Humanitarian Technology Conference (GHTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/GHTC.2017.8239306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

在供水系统中检测少量污染物的困难目前威胁着全世界数百万人的健康,因为饮用受污染的水与癌症和非癌症健康风险有关。现有技术可以非常准确地量化水中的污染物水平;然而,这些方法所需要的费用、广泛的培训和非现场分析阻碍了大规模使用。电化学检测具有许多优点,如便携性,仪器使用最少,与电子器件集成。以水质干预为目标,我们提出了一种经济实惠的使用点平台,能够检测水样中的少量砷。我们的电化学系统采用了一个三电极传感器,集成了一个手持式、自行设计的定位器Aquasift。Aquasift的硬件尽可能地简化,以保持可承受性,并依赖于固件的复杂性来提供与更昂贵的台式电位器相媲美的功能。几个可选的板载数字滤波器可用于信号调理。Aquasift可以以高达1KSPS的速率采样,输出数据速率可从1KSPS调整到每秒1个样本。该板使用12位数据转换器提供806微伏的电压分辨率。Aquasift直接从USB端口供电,不需要额外的电源。我们比较了从Aquasift砷测试获得的结果和从市售台式恒电位器获得的结果。结果表明,Aquasift的准确度与商用分析仪相当,并证明我们提出的系统是实验室测试的更实惠,便携的替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Aquasift: A low-cost, hand-held potentiostat for point-of-use electrochemical detection of contaminants in drinking water
The difficulty of detecting small quantities of contaminants in water supplies currently threatens the health of millions of people worldwide, as consumption of contaminated water has been associated with both cancerous and noncancerous health risks. Existing technologies make it possible to very accurately quantify contaminant levels in water; however the expense, extensive training, and off-site analysis required by these methods prevent wide scale use. Electrochemical detection offers many advantages, such as portability, minimal use of instrumentation, and ready integration with electronics. With a goal of water quality interventions, we have presented an affordable and point-of-use platform capable of detecting small amounts of arsenic in water samples. Our electrochemical system utilizes a three-electrode sensor integrated with a handheld, self-designed potentiostat called Aquasift. Aquasift's hardware is simplified as much as possible to maintain affordability and relies on firmware complexity to provide functionality comparable to more expensive bench top potentiostats. Several optional on-board digital filters are available for signal conditioning. The Aquasift can sample at a rate up to 1KSPS and the output data rate is adjustable from 1KSPS down to 1 sample per second. The board uses 12-bit data converters to provide a voltage resolution of 806 micro volts. The Aquasift is powered directly from the USB port and requires no additional power source. We compare the results obtained from the Aquasift of arsenic testing to those obtained from a commercially available bench top potentiostat. The results show Aquasift's comparable accuracy to the commercial analyzer, and demonstrate that our proposed system is a more affordable, portable alternative to laboratory testing.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Tablet app for child cognitive assessment in low and middle income countries Analyzing sub-optimal rural microgrids and methods for improving the system capacity and demand factors: Filibaba microgrid case study examined A global market assessment methodology for small wind in the developing world Using smart power management control to maximize energy utilization and reliability within a microgrid of interconnected solar home systems Use of cough sounds for diagnosis and screening of pulmonary disease
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1