基于LCC的高压直流系统故障时的直流分析

R. Hiremath, T. Moger
{"title":"基于LCC的高压直流系统故障时的直流分析","authors":"R. Hiremath, T. Moger","doi":"10.1109/UPEC50034.2021.9548167","DOIUrl":null,"url":null,"abstract":"The performance of the grid connected wind farms (WFs) with HVDC system is attracting much interest. Many WFs employ controllers for converter stations to provide a favourable grid support during fault. This paper focusses on the direct current analysis of the HVDC system during three phase (ϕ) fault. The paper has been proposed the \"DIgSILENT Simulation Language (DSL)\" based voltage dependant current order limiter (VDCOL) and PI controller for the converter stations. The DIgSILENT PowerFactory (DPF) software provides the platform to model the HVDC system for better DC current and voltage response under the fault. The stability of this system is analysed with the bode plot. The simulation results under the 3-phase fault indicate the better DC current and voltage behaviour.","PeriodicalId":325389,"journal":{"name":"2021 56th International Universities Power Engineering Conference (UPEC)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Direct Current Analysis of LCC based HVDC System during Fault using DIgSILENT PowerFactory\",\"authors\":\"R. Hiremath, T. Moger\",\"doi\":\"10.1109/UPEC50034.2021.9548167\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The performance of the grid connected wind farms (WFs) with HVDC system is attracting much interest. Many WFs employ controllers for converter stations to provide a favourable grid support during fault. This paper focusses on the direct current analysis of the HVDC system during three phase (ϕ) fault. The paper has been proposed the \\\"DIgSILENT Simulation Language (DSL)\\\" based voltage dependant current order limiter (VDCOL) and PI controller for the converter stations. The DIgSILENT PowerFactory (DPF) software provides the platform to model the HVDC system for better DC current and voltage response under the fault. The stability of this system is analysed with the bode plot. The simulation results under the 3-phase fault indicate the better DC current and voltage behaviour.\",\"PeriodicalId\":325389,\"journal\":{\"name\":\"2021 56th International Universities Power Engineering Conference (UPEC)\",\"volume\":\"14 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 56th International Universities Power Engineering Conference (UPEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/UPEC50034.2021.9548167\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 56th International Universities Power Engineering Conference (UPEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/UPEC50034.2021.9548167","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用高压直流输电系统的并网风电场的性能引起了人们的广泛关注。许多WFs采用换流站控制器,以便在故障时提供有利的电网支持。本文主要研究高压直流系统三相(φ)故障时的直流电流分析。本文提出了基于“DIgSILENT仿真语言(DSL)”的电压相关限流器(VDCOL)和PI控制器。DIgSILENT PowerFactory (DPF)软件提供了对高压直流系统建模的平台,以便在故障情况下更好地响应直流电流和电压。用波德图分析了该系统的稳定性。在三相故障情况下的仿真结果表明,该系统具有较好的直流电流和电压特性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Direct Current Analysis of LCC based HVDC System during Fault using DIgSILENT PowerFactory
The performance of the grid connected wind farms (WFs) with HVDC system is attracting much interest. Many WFs employ controllers for converter stations to provide a favourable grid support during fault. This paper focusses on the direct current analysis of the HVDC system during three phase (ϕ) fault. The paper has been proposed the "DIgSILENT Simulation Language (DSL)" based voltage dependant current order limiter (VDCOL) and PI controller for the converter stations. The DIgSILENT PowerFactory (DPF) software provides the platform to model the HVDC system for better DC current and voltage response under the fault. The stability of this system is analysed with the bode plot. The simulation results under the 3-phase fault indicate the better DC current and voltage behaviour.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Assessment of Methods to Measure Power System Flexibility: A Review Novel DPWM Modulation Scheme for Three-Phase ZVS Inverters Optimizing the turbines distribution in wind farms based on mutual minimization of the wake effect Modified Grid-forming Converter Control for Black-Start and Grid-Synchronization Applications Novel Hybrid Invasive Weed Optimization and Machine Learning Approach for Fault Detection
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1