J. Ryan, J. Campbell, K. Cheung, J. Suehle, R. Southwick, A. Oates
{"title":"高漏电设备的可靠性监测","authors":"J. Ryan, J. Campbell, K. Cheung, J. Suehle, R. Southwick, A. Oates","doi":"10.1109/IRPS.2013.6531960","DOIUrl":null,"url":null,"abstract":"We demonstrate a new charge pumping (CP) methodology, frequency modulated CP (FMCP), that robustly treats metrology challenges associated with high gate leakage current. By moving to an AC coupled measurement, we are able to easily resolve small CP signals despite excessively high gate leakage current backgrounds. We demonstrate the utility of FMCP as a reliability monitoring tool in highly scaled and highly leaky devices.","PeriodicalId":138206,"journal":{"name":"2013 IEEE International Reliability Physics Symposium (IRPS)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-04-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Reliability monitoring for highly leaky devices\",\"authors\":\"J. Ryan, J. Campbell, K. Cheung, J. Suehle, R. Southwick, A. Oates\",\"doi\":\"10.1109/IRPS.2013.6531960\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We demonstrate a new charge pumping (CP) methodology, frequency modulated CP (FMCP), that robustly treats metrology challenges associated with high gate leakage current. By moving to an AC coupled measurement, we are able to easily resolve small CP signals despite excessively high gate leakage current backgrounds. We demonstrate the utility of FMCP as a reliability monitoring tool in highly scaled and highly leaky devices.\",\"PeriodicalId\":138206,\"journal\":{\"name\":\"2013 IEEE International Reliability Physics Symposium (IRPS)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-04-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Reliability Physics Symposium (IRPS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IRPS.2013.6531960\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Reliability Physics Symposium (IRPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRPS.2013.6531960","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
We demonstrate a new charge pumping (CP) methodology, frequency modulated CP (FMCP), that robustly treats metrology challenges associated with high gate leakage current. By moving to an AC coupled measurement, we are able to easily resolve small CP signals despite excessively high gate leakage current backgrounds. We demonstrate the utility of FMCP as a reliability monitoring tool in highly scaled and highly leaky devices.