PET数据最大似然重建中的散点校正

M. Daube-Witherspoon, R. Carson, Y. Yan, T. K. Yap
{"title":"PET数据最大似然重建中的散点校正","authors":"M. Daube-Witherspoon, R. Carson, Y. Yan, T. K. Yap","doi":"10.1109/NSSMIC.1992.301098","DOIUrl":null,"url":null,"abstract":"To obtain quantitative PET (positron emission tomography) images with the ML (maximum likelihood) reconstruction algorithm, the authors investigated the inclusion of a correction for scatter. They implemented the spatially variant convolution method of M. Bergstrom et al. (J. Comput. Assist. Tomogr., vol.7, p.42-50, 1983) which assumes that scatter is independent of depth and collapses the problem to a projection-by-projection scatter model. The model was implemented in three ways: subtraction of scatter estimated from measured projections prior to reconstruction; inclusion of a scatter estimate from the measured projection data in the iteration loop; and inclusion of a scatter estimate in the iteration loop, based on the previous iteration's estimate of trues from the image. The reconstructions were performed on an Intel iPSC/860 hypercube computer. Analysis of the convergence, bias, and noise properties of the three methods of scatter correction demonstrated only slight differences between the methods for real phantom data taken on the Scanditronix PC2048-15B brain PET scanner. The structure of this ML algorithm permits direct extension to a more comprehensive model of scatter.<<ETX>>","PeriodicalId":447239,"journal":{"name":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"27","resultStr":"{\"title\":\"Scatter correction in maximum-likelihood reconstruction of PET data\",\"authors\":\"M. Daube-Witherspoon, R. Carson, Y. Yan, T. K. Yap\",\"doi\":\"10.1109/NSSMIC.1992.301098\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To obtain quantitative PET (positron emission tomography) images with the ML (maximum likelihood) reconstruction algorithm, the authors investigated the inclusion of a correction for scatter. They implemented the spatially variant convolution method of M. Bergstrom et al. (J. Comput. Assist. Tomogr., vol.7, p.42-50, 1983) which assumes that scatter is independent of depth and collapses the problem to a projection-by-projection scatter model. The model was implemented in three ways: subtraction of scatter estimated from measured projections prior to reconstruction; inclusion of a scatter estimate from the measured projection data in the iteration loop; and inclusion of a scatter estimate in the iteration loop, based on the previous iteration's estimate of trues from the image. The reconstructions were performed on an Intel iPSC/860 hypercube computer. Analysis of the convergence, bias, and noise properties of the three methods of scatter correction demonstrated only slight differences between the methods for real phantom data taken on the Scanditronix PC2048-15B brain PET scanner. The structure of this ML algorithm permits direct extension to a more comprehensive model of scatter.<<ETX>>\",\"PeriodicalId\":447239,\"journal\":{\"name\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1992-10-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Conference on Nuclear Science Symposium and Medical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.1992.301098\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Conference on Nuclear Science Symposium and Medical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.1992.301098","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27

摘要

为了使用最大似然重建算法获得定量PET(正电子发射断层扫描)图像,作者研究了包含散射校正的方法。他们实现了M. Bergstrom等人的空间变卷积方法。协助。Tomogr。, vol.7, p.42-50, 1983),它假设散射与深度无关,并将问题分解为逐投影的散射模型。该模型通过三种方式实现:在重建之前减去测量投影估计的散点;在迭代循环中包含来自测量投影数据的散点估计;并在迭代循环中包含一个散点估计,基于前一次迭代对图像真值的估计。在Intel iPSC/860超立方体计算机上进行重构。对三种散射校正方法的收敛性、偏置性和噪声特性的分析表明,在scanitronix PC2048-15B脑PET扫描仪上获取的真实幻象数据的方法之间只有轻微的差异。这种ML算法的结构允许直接扩展到更全面的散点模型。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Scatter correction in maximum-likelihood reconstruction of PET data
To obtain quantitative PET (positron emission tomography) images with the ML (maximum likelihood) reconstruction algorithm, the authors investigated the inclusion of a correction for scatter. They implemented the spatially variant convolution method of M. Bergstrom et al. (J. Comput. Assist. Tomogr., vol.7, p.42-50, 1983) which assumes that scatter is independent of depth and collapses the problem to a projection-by-projection scatter model. The model was implemented in three ways: subtraction of scatter estimated from measured projections prior to reconstruction; inclusion of a scatter estimate from the measured projection data in the iteration loop; and inclusion of a scatter estimate in the iteration loop, based on the previous iteration's estimate of trues from the image. The reconstructions were performed on an Intel iPSC/860 hypercube computer. Analysis of the convergence, bias, and noise properties of the three methods of scatter correction demonstrated only slight differences between the methods for real phantom data taken on the Scanditronix PC2048-15B brain PET scanner. The structure of this ML algorithm permits direct extension to a more comprehensive model of scatter.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Results in online data processing in the data acquisition system of the ALEPH TPC Practical evaluation of several cone beam orbits for SPECT Model based scatter correction in three dimensions (positron emission tomography) Macintosh software for simulating resolution and scatter effects in PET Testing fast ADC's at sample rates between 20 and 140 MSPS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1