现场演示:HemeChip -一种便携式微芯片电泳技术,用于镰状细胞病的即时筛查

M. N. Hasan, A. Fraiwan, U. Gurkan, J. Little
{"title":"现场演示:HemeChip -一种便携式微芯片电泳技术,用于镰状细胞病的即时筛查","authors":"M. N. Hasan, A. Fraiwan, U. Gurkan, J. Little","doi":"10.1109/BIOCAS.2018.8584795","DOIUrl":null,"url":null,"abstract":"HemeChip is the first miniaturized, single-use cartridge-based microchip electrophoresis system for identifying and quantifying hemoglobin (Hb) variants from a drop of blood at the point-of-care (POC). It is estimated that 7% of world's population lives with a hemoglobin variant, and one of the most common and severe one being the recessively transmitted sickle hemoglobin which results in Sickle Cell Disease (SCD). HemeChip (Fig. 1A,C) separates Hb variants on a strip of cellulose acetate (CA) paper that is housed in the HemeChip cartridge. This HemeChip cartridge is a mass-producible, single-use cartridge that maintains a controlled environment and a constant electric field (applied through the electrodes, Fig. 1B) for the Hb separation process. The cartridge also contains an in-chip blotting mechanism and an anti-fogging feature. The anti-fogging feature is essential for real-time imaging and tracking of Hb band(s) during the separation process. HemeChip is integrated with a portable reader (Fig. 1D) to detect the type(s) and fraction of hemoglobin types present in a blood sample. HemeChip technology has been designed and developed to offer a robust, user-friendly platform to detect, identify, and quantify Hb variants (responsible for SCD variants) even in a limited resource settings.","PeriodicalId":259162,"journal":{"name":"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)","volume":"04 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Live Demonstration: HemeChip - A Portable Microchip Electrophoresis Technology for Point-of-Care Sickle Cell Disease Screening\",\"authors\":\"M. N. Hasan, A. Fraiwan, U. Gurkan, J. Little\",\"doi\":\"10.1109/BIOCAS.2018.8584795\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"HemeChip is the first miniaturized, single-use cartridge-based microchip electrophoresis system for identifying and quantifying hemoglobin (Hb) variants from a drop of blood at the point-of-care (POC). It is estimated that 7% of world's population lives with a hemoglobin variant, and one of the most common and severe one being the recessively transmitted sickle hemoglobin which results in Sickle Cell Disease (SCD). HemeChip (Fig. 1A,C) separates Hb variants on a strip of cellulose acetate (CA) paper that is housed in the HemeChip cartridge. This HemeChip cartridge is a mass-producible, single-use cartridge that maintains a controlled environment and a constant electric field (applied through the electrodes, Fig. 1B) for the Hb separation process. The cartridge also contains an in-chip blotting mechanism and an anti-fogging feature. The anti-fogging feature is essential for real-time imaging and tracking of Hb band(s) during the separation process. HemeChip is integrated with a portable reader (Fig. 1D) to detect the type(s) and fraction of hemoglobin types present in a blood sample. HemeChip technology has been designed and developed to offer a robust, user-friendly platform to detect, identify, and quantify Hb variants (responsible for SCD variants) even in a limited resource settings.\",\"PeriodicalId\":259162,\"journal\":{\"name\":\"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"volume\":\"04 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BIOCAS.2018.8584795\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Biomedical Circuits and Systems Conference (BioCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOCAS.2018.8584795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

HemeChip是首个小型化、一次性使用的微晶片电泳系统,用于在护理点(POC)鉴定和定量一滴血中的血红蛋白(Hb)变异。据估计,世界上7%的人口患有一种血红蛋白变异,其中最常见和最严重的一种是隐性传播的镰状血红蛋白,可导致镰状细胞病(SCD)。HemeChip(图1A,C)在放置在HemeChip药盒中的醋酸纤维素(CA)纸条上分离Hb变体。HemeChip墨盒是一种可批量生产的一次性墨盒,可保持受控环境和恒定电场(通过电极施加,图1B),用于Hb分离过程。墨盒还包含一个芯片内印迹机制和防雾功能。在分离过程中,抗雾特性对于Hb波段的实时成像和跟踪至关重要。HemeChip集成了便携式读取器(图1D),用于检测血液样本中存在的血红蛋白类型和比例。HemeChip技术的设计和开发提供了一个强大的、用户友好的平台,即使在资源有限的情况下,也可以检测、识别和量化Hb变异(负责SCD变异)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Live Demonstration: HemeChip - A Portable Microchip Electrophoresis Technology for Point-of-Care Sickle Cell Disease Screening
HemeChip is the first miniaturized, single-use cartridge-based microchip electrophoresis system for identifying and quantifying hemoglobin (Hb) variants from a drop of blood at the point-of-care (POC). It is estimated that 7% of world's population lives with a hemoglobin variant, and one of the most common and severe one being the recessively transmitted sickle hemoglobin which results in Sickle Cell Disease (SCD). HemeChip (Fig. 1A,C) separates Hb variants on a strip of cellulose acetate (CA) paper that is housed in the HemeChip cartridge. This HemeChip cartridge is a mass-producible, single-use cartridge that maintains a controlled environment and a constant electric field (applied through the electrodes, Fig. 1B) for the Hb separation process. The cartridge also contains an in-chip blotting mechanism and an anti-fogging feature. The anti-fogging feature is essential for real-time imaging and tracking of Hb band(s) during the separation process. HemeChip is integrated with a portable reader (Fig. 1D) to detect the type(s) and fraction of hemoglobin types present in a blood sample. HemeChip technology has been designed and developed to offer a robust, user-friendly platform to detect, identify, and quantify Hb variants (responsible for SCD variants) even in a limited resource settings.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Smart Prosthesis System: Continuous Automatic Prosthesis Fitting Adjustment and Real-time Stress Visualization Framework of Applying Independent Component Analysis After Compressed Sensing for Electroencephalogram Signals Live Demonstration: A Bluetooth Low Energy (BLE)-enabled Wireless Link for Bidirectional Communications with a Neural Microsystem The Spectral Calibration of Swept-Source Optical Coherence Tomography Systems Using Unscented Kalman Filter An Ultra-Wideband-Inspired System-on-Chip for an Optical Bidirectional Transcutaneous Biotelemetry
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1