CO2激光诱导辐照聚烯二甘醇聚合物的微观结构变化

M. AlSalhi, W. A. Farooq, M. R. Baig, A. H Al-Fareikh, S. S. Al-ghamdi
{"title":"CO2激光诱导辐照聚烯二甘醇聚合物的微观结构变化","authors":"M. AlSalhi, W. A. Farooq, M. R. Baig, A. H Al-Fareikh, S. S. Al-ghamdi","doi":"10.1109/SIECPC.2011.5876927","DOIUrl":null,"url":null,"abstract":"The effect of post-irradiation of CO2 laser at wavelength of 10.6μm, as a coherent source, on the alpha irradiated polyallydiglycol track recorder has been investigated to study the detector characteristics due to the corresponding morphology modifications. The average bulk etch rate and the mean diameter of alpha tracks are studied at several laser powers. In addition to this, absorption of the irradiated samples have also been investigated from 200nm to 600nm to observe the change in optical band-gap and it is concluded that the variation in the mean diameter of alpha tracks is probably linked to the variation in optical band-gap.","PeriodicalId":125634,"journal":{"name":"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CO2 laser induced micro structural variation in alpha-irradiated Polyallydigycol polymer\",\"authors\":\"M. AlSalhi, W. A. Farooq, M. R. Baig, A. H Al-Fareikh, S. S. Al-ghamdi\",\"doi\":\"10.1109/SIECPC.2011.5876927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of post-irradiation of CO2 laser at wavelength of 10.6μm, as a coherent source, on the alpha irradiated polyallydiglycol track recorder has been investigated to study the detector characteristics due to the corresponding morphology modifications. The average bulk etch rate and the mean diameter of alpha tracks are studied at several laser powers. In addition to this, absorption of the irradiated samples have also been investigated from 200nm to 600nm to observe the change in optical band-gap and it is concluded that the variation in the mean diameter of alpha tracks is probably linked to the variation in optical band-gap.\",\"PeriodicalId\":125634,\"journal\":{\"name\":\"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SIECPC.2011.5876927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 Saudi International Electronics, Communications and Photonics Conference (SIECPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SIECPC.2011.5876927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了波长为10.6μm的CO2激光作为相干源辐照后对α辐照聚烯二甘醇轨迹记录仪的影响,研究了其形貌变化对探测器特性的影响。研究了不同激光功率下的平均体蚀率和径迹的平均直径。除此之外,我们还研究了辐照样品在200nm到600nm范围内的吸收情况,观察了光学带隙的变化,得出了α径迹平均直径的变化可能与光学带隙的变化有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CO2 laser induced micro structural variation in alpha-irradiated Polyallydigycol polymer
The effect of post-irradiation of CO2 laser at wavelength of 10.6μm, as a coherent source, on the alpha irradiated polyallydiglycol track recorder has been investigated to study the detector characteristics due to the corresponding morphology modifications. The average bulk etch rate and the mean diameter of alpha tracks are studied at several laser powers. In addition to this, absorption of the irradiated samples have also been investigated from 200nm to 600nm to observe the change in optical band-gap and it is concluded that the variation in the mean diameter of alpha tracks is probably linked to the variation in optical band-gap.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Copyright page Frequency invariant beamforming using sensor delay line Building energy efficient LR-PON for desert terrain of Saudi Arabia Adaptive UWB-OFDM Synthetic Aperture Radar Analysis of Bus-Invert coding in the presence of correlations
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1