Fusheng Wang, Xiaofei Wang, Zhangping Shao, Xing Zhang, Ping Liu
{"title":"三电平模块化并网光伏系统差模循环电流减小","authors":"Fusheng Wang, Xiaofei Wang, Zhangping Shao, Xing Zhang, Ping Liu","doi":"10.1109/TENCON.2013.6718923","DOIUrl":null,"url":null,"abstract":"According to the problem that differential mode circulating current exists in the three-level modular grid-connected photovoltaic system with LC filter, the equivalent model of differential mode circulating current was proposed in this paper. Differential mode circulating current was divided into two types according to different loops. The admittance curve of differential mode circulating current between frequency and leakage inductance ratio was analyzed, and the conclusion was made that the first type of differential mode circulating current is much larger than the second type. Then, the parallel scheme with LCL filter is used, and the inductance ratio is reasonably designed to reduce the differential mode circulating current effectively. A three-level modular grid-connected photovoltaic system rated 10kW was built, and simulation results and experimental results demonstrate the correctness of the model analysis and reduction methods of zero-sequence circulating current.","PeriodicalId":425023,"journal":{"name":"2013 IEEE International Conference of IEEE Region 10 (TENCON 2013)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Differential mode circulating current reduction for three-level modular grid-connected photovoltaic system\",\"authors\":\"Fusheng Wang, Xiaofei Wang, Zhangping Shao, Xing Zhang, Ping Liu\",\"doi\":\"10.1109/TENCON.2013.6718923\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"According to the problem that differential mode circulating current exists in the three-level modular grid-connected photovoltaic system with LC filter, the equivalent model of differential mode circulating current was proposed in this paper. Differential mode circulating current was divided into two types according to different loops. The admittance curve of differential mode circulating current between frequency and leakage inductance ratio was analyzed, and the conclusion was made that the first type of differential mode circulating current is much larger than the second type. Then, the parallel scheme with LCL filter is used, and the inductance ratio is reasonably designed to reduce the differential mode circulating current effectively. A three-level modular grid-connected photovoltaic system rated 10kW was built, and simulation results and experimental results demonstrate the correctness of the model analysis and reduction methods of zero-sequence circulating current.\",\"PeriodicalId\":425023,\"journal\":{\"name\":\"2013 IEEE International Conference of IEEE Region 10 (TENCON 2013)\",\"volume\":\"15 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE International Conference of IEEE Region 10 (TENCON 2013)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TENCON.2013.6718923\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE International Conference of IEEE Region 10 (TENCON 2013)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TENCON.2013.6718923","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Differential mode circulating current reduction for three-level modular grid-connected photovoltaic system
According to the problem that differential mode circulating current exists in the three-level modular grid-connected photovoltaic system with LC filter, the equivalent model of differential mode circulating current was proposed in this paper. Differential mode circulating current was divided into two types according to different loops. The admittance curve of differential mode circulating current between frequency and leakage inductance ratio was analyzed, and the conclusion was made that the first type of differential mode circulating current is much larger than the second type. Then, the parallel scheme with LCL filter is used, and the inductance ratio is reasonably designed to reduce the differential mode circulating current effectively. A three-level modular grid-connected photovoltaic system rated 10kW was built, and simulation results and experimental results demonstrate the correctness of the model analysis and reduction methods of zero-sequence circulating current.