Xin Yang, Xixiu Wu, Jin Qiu, Chao Li, Bo Wen, Hui Hou, Tao Yang, Liang Huang
{"title":"隔离操作对GIS空间辐射电磁干扰特性的影响","authors":"Xin Yang, Xixiu Wu, Jin Qiu, Chao Li, Bo Wen, Hui Hou, Tao Yang, Liang Huang","doi":"10.1109/ICEPE-ST.2019.8928872","DOIUrl":null,"url":null,"abstract":"GIS switchgear operation is the main EMI source of the smart substation which will disturb the normal work of intelligent component and results severe electric power accident. To ensure the safety and reliability of smart GIS substation, it is quite necessary to carry out research on the EMI characteristics of GIS spatial radiation caused by disconnector operation. For this reason, a 550kV GIS experimental platform with very complex measurement system is set up and biconical antenna is applied to measure the electric filed radiation during the test. The measurement results show that: ① The amplitude of electric filed radiation is very high, which fluctuates at the range of 1.931kV/m~2.458kV/m; ② The EMI duration of DS operation last for long time, 5-7 cycle time for open operation and 3-5 cycle time for close operation respectively; ③The electric filed radiation has abundant frequency component and 1MHz,7.5MHz,14.5MHz and 46.5MHz are the characteristic frequency of it.","PeriodicalId":392306,"journal":{"name":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Study on the Spatial Radiation EMI Characteristics of GIS Caused by Disconnector Operation\",\"authors\":\"Xin Yang, Xixiu Wu, Jin Qiu, Chao Li, Bo Wen, Hui Hou, Tao Yang, Liang Huang\",\"doi\":\"10.1109/ICEPE-ST.2019.8928872\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"GIS switchgear operation is the main EMI source of the smart substation which will disturb the normal work of intelligent component and results severe electric power accident. To ensure the safety and reliability of smart GIS substation, it is quite necessary to carry out research on the EMI characteristics of GIS spatial radiation caused by disconnector operation. For this reason, a 550kV GIS experimental platform with very complex measurement system is set up and biconical antenna is applied to measure the electric filed radiation during the test. The measurement results show that: ① The amplitude of electric filed radiation is very high, which fluctuates at the range of 1.931kV/m~2.458kV/m; ② The EMI duration of DS operation last for long time, 5-7 cycle time for open operation and 3-5 cycle time for close operation respectively; ③The electric filed radiation has abundant frequency component and 1MHz,7.5MHz,14.5MHz and 46.5MHz are the characteristic frequency of it.\",\"PeriodicalId\":392306,\"journal\":{\"name\":\"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEPE-ST.2019.8928872\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEPE-ST.2019.8928872","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Study on the Spatial Radiation EMI Characteristics of GIS Caused by Disconnector Operation
GIS switchgear operation is the main EMI source of the smart substation which will disturb the normal work of intelligent component and results severe electric power accident. To ensure the safety and reliability of smart GIS substation, it is quite necessary to carry out research on the EMI characteristics of GIS spatial radiation caused by disconnector operation. For this reason, a 550kV GIS experimental platform with very complex measurement system is set up and biconical antenna is applied to measure the electric filed radiation during the test. The measurement results show that: ① The amplitude of electric filed radiation is very high, which fluctuates at the range of 1.931kV/m~2.458kV/m; ② The EMI duration of DS operation last for long time, 5-7 cycle time for open operation and 3-5 cycle time for close operation respectively; ③The electric filed radiation has abundant frequency component and 1MHz,7.5MHz,14.5MHz and 46.5MHz are the characteristic frequency of it.