Andreas Koenig, T. Plum, Peter Fidler, R. D. Doncker
{"title":"CoolMOS器件结温在线测量","authors":"Andreas Koenig, T. Plum, Peter Fidler, R. D. Doncker","doi":"10.1109/PEDS.2007.4487683","DOIUrl":null,"url":null,"abstract":"To operate power electronic devices at high ambient temperatures it has to be ensured that the maximum specified junction temperature is not exceeded at any time during operation. This paper presents a method to calculate the actual junction temperature by measuring voltage and current at a power MOSFET during operation of a converter. Based on this temperature, the actual transferred power of a converter can be controlled to ensure a safe operation within the specified temperature limits.","PeriodicalId":166704,"journal":{"name":"2007 7th International Conference on Power Electronics and Drive Systems","volume":"19 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"54","resultStr":"{\"title\":\"On-line Junction Temperature Measurement of CoolMOS Devices\",\"authors\":\"Andreas Koenig, T. Plum, Peter Fidler, R. D. Doncker\",\"doi\":\"10.1109/PEDS.2007.4487683\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To operate power electronic devices at high ambient temperatures it has to be ensured that the maximum specified junction temperature is not exceeded at any time during operation. This paper presents a method to calculate the actual junction temperature by measuring voltage and current at a power MOSFET during operation of a converter. Based on this temperature, the actual transferred power of a converter can be controlled to ensure a safe operation within the specified temperature limits.\",\"PeriodicalId\":166704,\"journal\":{\"name\":\"2007 7th International Conference on Power Electronics and Drive Systems\",\"volume\":\"19 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"54\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 7th International Conference on Power Electronics and Drive Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDS.2007.4487683\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 7th International Conference on Power Electronics and Drive Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDS.2007.4487683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
On-line Junction Temperature Measurement of CoolMOS Devices
To operate power electronic devices at high ambient temperatures it has to be ensured that the maximum specified junction temperature is not exceeded at any time during operation. This paper presents a method to calculate the actual junction temperature by measuring voltage and current at a power MOSFET during operation of a converter. Based on this temperature, the actual transferred power of a converter can be controlled to ensure a safe operation within the specified temperature limits.