非线性负载对EMI/RFI滤波器的影响

S. J. Briggs, D. Savignon, P. Krein, M.S. Kim
{"title":"非线性负载对EMI/RFI滤波器的影响","authors":"S. J. Briggs, D. Savignon, P. Krein, M.S. Kim","doi":"10.1109/ICPS.1994.303559","DOIUrl":null,"url":null,"abstract":"Power feeder electromagnetic interference/radio frequency interference (EMI/RFI) filters are widely used in the US Army and industry for filtering unwanted signals on power lines supplying sensitive loads such as computers and communication equipment. Typically these low pass filters are passive circuits designed to attenuate frequencies above 10 kHz. Under 60 Hz sinusoidal conditions, the filters dissipate little power. But when nonlinear loads are present (such as those associated with computers, adjustable speed drives, electronic power supplies, and communication equipment), significant power dissipation can occur within the filters. This can shorten filter lifetime or even lead to complete filter failure. Laboratory testing and mathematical analyses were performed on a selected EMI/RFI filter to: (1) determine its frequency response in the 60 Hz to 3 kHz range; (2) identify the filter components that dissipate the most power when subjected to harmonic currents; and (3) measure filter component temperature rises when harmonic line currents are present. It is shown that power line harmonics, not considered by EMI/RFI filter manufacturers, interact with filter component parasitics and cause considerable power dissipation in the filters.<<ETX>>","PeriodicalId":197013,"journal":{"name":"Proceedings of Industrial and Commercial Power Systems Conference","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effects of nonlinear loads on EMI/RFI filters\",\"authors\":\"S. J. Briggs, D. Savignon, P. Krein, M.S. Kim\",\"doi\":\"10.1109/ICPS.1994.303559\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power feeder electromagnetic interference/radio frequency interference (EMI/RFI) filters are widely used in the US Army and industry for filtering unwanted signals on power lines supplying sensitive loads such as computers and communication equipment. Typically these low pass filters are passive circuits designed to attenuate frequencies above 10 kHz. Under 60 Hz sinusoidal conditions, the filters dissipate little power. But when nonlinear loads are present (such as those associated with computers, adjustable speed drives, electronic power supplies, and communication equipment), significant power dissipation can occur within the filters. This can shorten filter lifetime or even lead to complete filter failure. Laboratory testing and mathematical analyses were performed on a selected EMI/RFI filter to: (1) determine its frequency response in the 60 Hz to 3 kHz range; (2) identify the filter components that dissipate the most power when subjected to harmonic currents; and (3) measure filter component temperature rises when harmonic line currents are present. It is shown that power line harmonics, not considered by EMI/RFI filter manufacturers, interact with filter component parasitics and cause considerable power dissipation in the filters.<<ETX>>\",\"PeriodicalId\":197013,\"journal\":{\"name\":\"Proceedings of Industrial and Commercial Power Systems Conference\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1900-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Industrial and Commercial Power Systems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPS.1994.303559\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Industrial and Commercial Power Systems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPS.1994.303559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电源馈线电磁干扰/射频干扰(EMI/RFI)滤波器广泛用于美国陆军和工业中,用于过滤供电敏感负载(如计算机和通信设备)的电力线上不需要的信号。通常这些低通滤波器是无源电路,设计用于衰减10khz以上的频率。在60 Hz正弦条件下,滤波器功耗很小。但是,当存在非线性负载时(例如与计算机、可调速驱动器、电子电源和通信设备相关的负载),滤波器内可能会出现显著的功耗。这可能会缩短过滤器的使用寿命,甚至导致过滤器完全失效。对选定的EMI/RFI滤波器进行了实验室测试和数学分析,以:(1)确定其在60 Hz至3 kHz范围内的频率响应;(2)确定在谐波电流下耗散功率最大的滤波器元件;(3)测量谐波电流存在时滤波器元件温升。研究表明,EMI/RFI滤波器制造商没有考虑到的电力线谐波与滤波器组件寄生相互作用,并在滤波器中造成相当大的功耗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The effects of nonlinear loads on EMI/RFI filters
Power feeder electromagnetic interference/radio frequency interference (EMI/RFI) filters are widely used in the US Army and industry for filtering unwanted signals on power lines supplying sensitive loads such as computers and communication equipment. Typically these low pass filters are passive circuits designed to attenuate frequencies above 10 kHz. Under 60 Hz sinusoidal conditions, the filters dissipate little power. But when nonlinear loads are present (such as those associated with computers, adjustable speed drives, electronic power supplies, and communication equipment), significant power dissipation can occur within the filters. This can shorten filter lifetime or even lead to complete filter failure. Laboratory testing and mathematical analyses were performed on a selected EMI/RFI filter to: (1) determine its frequency response in the 60 Hz to 3 kHz range; (2) identify the filter components that dissipate the most power when subjected to harmonic currents; and (3) measure filter component temperature rises when harmonic line currents are present. It is shown that power line harmonics, not considered by EMI/RFI filter manufacturers, interact with filter component parasitics and cause considerable power dissipation in the filters.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Load modelling in commercial power systems using neural networks Characterization of power quality problems associated with large commercial customers served from large underground distribution network systems Fault analysis of multi-phase unbalanced non-radial power distribution systems Conversion of stand-by-generator facilities to combined heat and power units Electrical power system reliability case studies for water and wastewater treatment facilities
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1