投影电容阵列传感在医疗保健中的应用

Wen-Ying Chang, Chi-Chun Chen, Chin-Lung Yang
{"title":"投影电容阵列传感在医疗保健中的应用","authors":"Wen-Ying Chang, Chi-Chun Chen, Chin-Lung Yang","doi":"10.1109/ISBB.2014.6820896","DOIUrl":null,"url":null,"abstract":"This paper presents a cost-effective sensor system for the applications of large area array sensing. Unlike the traditional pressure sensing methods, projected capacitor technologies are proposed for sensing. The rapid charge time method is utilized to measure the capacitance values of the projected capacitive array electrodes. By constructing the process of projected capacitive array electrode, the required characteristics of the projected capacitor are identified, especially characteristics for large area applications. Three main factors, the area of electrodes, the use of shielding and gap between the guard ring and the electrode, also affect the capacitance primary value especially in the large-size applications. At last, a flexible projected capacitive sensing array with 8 × 10 electrodes was implemented to validate the feasibility of projected capacitive array electrodes.","PeriodicalId":265886,"journal":{"name":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"The applications of projected capacitive array sensing in healthcare\",\"authors\":\"Wen-Ying Chang, Chi-Chun Chen, Chin-Lung Yang\",\"doi\":\"10.1109/ISBB.2014.6820896\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a cost-effective sensor system for the applications of large area array sensing. Unlike the traditional pressure sensing methods, projected capacitor technologies are proposed for sensing. The rapid charge time method is utilized to measure the capacitance values of the projected capacitive array electrodes. By constructing the process of projected capacitive array electrode, the required characteristics of the projected capacitor are identified, especially characteristics for large area applications. Three main factors, the area of electrodes, the use of shielding and gap between the guard ring and the electrode, also affect the capacitance primary value especially in the large-size applications. At last, a flexible projected capacitive sensing array with 8 × 10 electrodes was implemented to validate the feasibility of projected capacitive array electrodes.\",\"PeriodicalId\":265886,\"journal\":{\"name\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"volume\":\"54 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISBB.2014.6820896\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB 2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISBB.2014.6820896","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本文提出了一种适用于大面积阵列传感应用的高性价比传感器系统。与传统的压力传感方法不同,投影电容技术被提出用于传感。采用快速充电时间法测量投影电容阵列电极的电容值。通过构建投射电容阵列电极的工艺,确定了投射电容所需的特性,特别是大面积应用的特性。三个主要因素,即电极的面积,屏蔽的使用以及保护环与电极之间的间隙,也会影响电容初级值,特别是在大尺寸应用中。最后,设计了一个8 × 10个电极的柔性投影电容传感阵列,验证了投影电容阵列电极的可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The applications of projected capacitive array sensing in healthcare
This paper presents a cost-effective sensor system for the applications of large area array sensing. Unlike the traditional pressure sensing methods, projected capacitor technologies are proposed for sensing. The rapid charge time method is utilized to measure the capacitance values of the projected capacitive array electrodes. By constructing the process of projected capacitive array electrode, the required characteristics of the projected capacitor are identified, especially characteristics for large area applications. Three main factors, the area of electrodes, the use of shielding and gap between the guard ring and the electrode, also affect the capacitance primary value especially in the large-size applications. At last, a flexible projected capacitive sensing array with 8 × 10 electrodes was implemented to validate the feasibility of projected capacitive array electrodes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stereoscopic laparoscopy using depth information from 3D model Analysis of the multiple ultrasound echoes for measurement of cortical bone thickness Smart cane: Instrumentation of a quad cane with audio-feedback monitoring system for partial weight-bearing support A low power high CMRR CMOS instrumentation amplifier for Bio-impedance Spectroscopy A novel approach for ECG data compression in healthcare monitoring system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1