智能电网中的高压直流连接:VSC变流器的通用控制策略

D. Lauria, F. Mottola, C. Pisani, Francesco Del Pizzo, E. Carlini, G. Giannuzzi
{"title":"智能电网中的高压直流连接:VSC变流器的通用控制策略","authors":"D. Lauria, F. Mottola, C. Pisani, Francesco Del Pizzo, E. Carlini, G. Giannuzzi","doi":"10.1109/AEITHVDC52364.2021.9474598","DOIUrl":null,"url":null,"abstract":"The forced switching converters are the kernel of the modern paradigm of VSC-HVDC system. It is widely recognized that appropriate control laws make these converters more advantageous than the traditional line commutated ones. They can play a versatile role by properly controlling active and reactive powers between electrical networks, improving the dynamic performances of the whole system. Besides this is more and more motivated by the wide spreading penetration of renewable resources. In this paper after a few references to basic concepts, a possible control strategy of VSC-HVDC transmission system is discussed. With respect to a two-area system with AC-DC link, a combined control law is investigated for improving inertial and primary frequency response. The control law is based upon the equivalent HVDC tie link synchronization coefficient which allows determining the reference value of the AC voltage reference angles of the converters. A damping action is further added for improving the power swings damping. The simulations performed with a simple but quite general case study permit to confirm the validity and the goodness of the proposed control strategy.","PeriodicalId":403034,"journal":{"name":"2021 AEIT HVDC International Conference (AEIT HVDC)","volume":"3 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"HVDC tie links in smart power grids: a versatile control strategy of VSC converters\",\"authors\":\"D. Lauria, F. Mottola, C. Pisani, Francesco Del Pizzo, E. Carlini, G. Giannuzzi\",\"doi\":\"10.1109/AEITHVDC52364.2021.9474598\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The forced switching converters are the kernel of the modern paradigm of VSC-HVDC system. It is widely recognized that appropriate control laws make these converters more advantageous than the traditional line commutated ones. They can play a versatile role by properly controlling active and reactive powers between electrical networks, improving the dynamic performances of the whole system. Besides this is more and more motivated by the wide spreading penetration of renewable resources. In this paper after a few references to basic concepts, a possible control strategy of VSC-HVDC transmission system is discussed. With respect to a two-area system with AC-DC link, a combined control law is investigated for improving inertial and primary frequency response. The control law is based upon the equivalent HVDC tie link synchronization coefficient which allows determining the reference value of the AC voltage reference angles of the converters. A damping action is further added for improving the power swings damping. The simulations performed with a simple but quite general case study permit to confirm the validity and the goodness of the proposed control strategy.\",\"PeriodicalId\":403034,\"journal\":{\"name\":\"2021 AEIT HVDC International Conference (AEIT HVDC)\",\"volume\":\"3 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 AEIT HVDC International Conference (AEIT HVDC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/AEITHVDC52364.2021.9474598\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 AEIT HVDC International Conference (AEIT HVDC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AEITHVDC52364.2021.9474598","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

强制开关变流器是现代直流—高压直流系统的核心。人们普遍认为,适当的控制律使这些变换器比传统的线路换向变换器更有优势。通过合理地控制电网间的有功和无功功率,改善整个系统的动态性能,可以发挥多种作用。此外,可再生资源的广泛普及也越来越推动了这一趋势。本文在参考了一些基本概念的基础上,讨论了一种可能的直流-直流输电系统控制策略。针对交直流两区系统,研究了一种改善惯性频率响应和主频率响应的组合控制律。该控制律基于等价的高压直流并网同步系数,可以确定变流器交流电压参考角的参考值。进一步增加了阻尼作用,以改善功率振荡阻尼。通过一个简单但非常普遍的案例研究进行了仿真,证实了所提出控制策略的有效性和优越性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
HVDC tie links in smart power grids: a versatile control strategy of VSC converters
The forced switching converters are the kernel of the modern paradigm of VSC-HVDC system. It is widely recognized that appropriate control laws make these converters more advantageous than the traditional line commutated ones. They can play a versatile role by properly controlling active and reactive powers between electrical networks, improving the dynamic performances of the whole system. Besides this is more and more motivated by the wide spreading penetration of renewable resources. In this paper after a few references to basic concepts, a possible control strategy of VSC-HVDC transmission system is discussed. With respect to a two-area system with AC-DC link, a combined control law is investigated for improving inertial and primary frequency response. The control law is based upon the equivalent HVDC tie link synchronization coefficient which allows determining the reference value of the AC voltage reference angles of the converters. A damping action is further added for improving the power swings damping. The simulations performed with a simple but quite general case study permit to confirm the validity and the goodness of the proposed control strategy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Selective Harmonic Elimination Modulation for HVDC Modular Multilevel Converter Active and Reactive Power control of Italy – Montenegro HVDC First year of operation Converting Overhead Lines from HVAC to HVDC: an Overview Analysis Innovative Converter Testing Technology and Overall Reliability and Availability Performance of HVDC Solutions Modulating Signals Effect on Capacitor Voltage Ripple in Full Bridge Modular Multilevel Converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1