{"title":"电力系统中超导发电机的动态稳定性","authors":"I. Muta, K. Yoshimoto, T. Hoshino, T. Nakamura","doi":"10.1109/ICEMS.2001.970763","DOIUrl":null,"url":null,"abstract":"This paper presents the dynamic stability of a superconducting generator of 200 MW class connected to an infinite busbar through a power transmission line. Details regarding damping ratio, nondamped natural frequency and output power limit of the machine have been investigated. Furthermore, a superconducting generator system with series-connected capacitor in the power transmission-fine has been studied from the viewpoint of stability improvement. This paper also examines dynamic performances dependence upon control systems such as AVR and GOV (Governor).","PeriodicalId":143007,"journal":{"name":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","volume":"42 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2001-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dynamic stability of a superconducting generator in the electric power system\",\"authors\":\"I. Muta, K. Yoshimoto, T. Hoshino, T. Nakamura\",\"doi\":\"10.1109/ICEMS.2001.970763\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the dynamic stability of a superconducting generator of 200 MW class connected to an infinite busbar through a power transmission line. Details regarding damping ratio, nondamped natural frequency and output power limit of the machine have been investigated. Furthermore, a superconducting generator system with series-connected capacitor in the power transmission-fine has been studied from the viewpoint of stability improvement. This paper also examines dynamic performances dependence upon control systems such as AVR and GOV (Governor).\",\"PeriodicalId\":143007,\"journal\":{\"name\":\"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)\",\"volume\":\"42 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-08-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMS.2001.970763\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICEMS'2001. Proceedings of the Fifth International Conference on Electrical Machines and Systems (IEEE Cat. No.01EX501)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMS.2001.970763","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Dynamic stability of a superconducting generator in the electric power system
This paper presents the dynamic stability of a superconducting generator of 200 MW class connected to an infinite busbar through a power transmission line. Details regarding damping ratio, nondamped natural frequency and output power limit of the machine have been investigated. Furthermore, a superconducting generator system with series-connected capacitor in the power transmission-fine has been studied from the viewpoint of stability improvement. This paper also examines dynamic performances dependence upon control systems such as AVR and GOV (Governor).