{"title":"利用瞳孔和角膜反射信号进行微扫视检测","authors":"D. Niehorster, M. Nyström","doi":"10.1145/3204493.3204573","DOIUrl":null,"url":null,"abstract":"In contemporary research, microsaccade detection is typically performed using the calibrated gaze-velocity signal acquired from a video-based eye tracker. To generate this signal, the pupil and corneal reflection (CR) signals are subtracted from each other and a differentiation filter is applied, both of which may prevent small microsaccades from being detected due to signal distortion and noise amplification. We propose a new algorithm where microsaccades are detected directly from uncalibrated pupil-, and CR signals. It is based on detrending followed by windowed correlation between pupil and CR signals. The proposed algorithm outperforms the most commonly used algorithm in the field (Engbert & Kliegl, 2003), in particular for small amplitude microsaccades that are difficult to see in the velocity signal even with the naked eye. We argue that it is advantageous to consider the most basic output of the eye tracker, i.e. pupil-, and CR signals, when detecting small microsaccades.","PeriodicalId":237808,"journal":{"name":"Proceedings of the 2018 ACM Symposium on Eye Tracking Research & Applications","volume":"50 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Microsaccade detection using pupil and corneal reflection signals\",\"authors\":\"D. Niehorster, M. Nyström\",\"doi\":\"10.1145/3204493.3204573\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In contemporary research, microsaccade detection is typically performed using the calibrated gaze-velocity signal acquired from a video-based eye tracker. To generate this signal, the pupil and corneal reflection (CR) signals are subtracted from each other and a differentiation filter is applied, both of which may prevent small microsaccades from being detected due to signal distortion and noise amplification. We propose a new algorithm where microsaccades are detected directly from uncalibrated pupil-, and CR signals. It is based on detrending followed by windowed correlation between pupil and CR signals. The proposed algorithm outperforms the most commonly used algorithm in the field (Engbert & Kliegl, 2003), in particular for small amplitude microsaccades that are difficult to see in the velocity signal even with the naked eye. We argue that it is advantageous to consider the most basic output of the eye tracker, i.e. pupil-, and CR signals, when detecting small microsaccades.\",\"PeriodicalId\":237808,\"journal\":{\"name\":\"Proceedings of the 2018 ACM Symposium on Eye Tracking Research & Applications\",\"volume\":\"50 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 2018 ACM Symposium on Eye Tracking Research & Applications\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/3204493.3204573\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 2018 ACM Symposium on Eye Tracking Research & Applications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/3204493.3204573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在当代研究中,通常使用基于视频的眼动仪获得的校准的注视速度信号来进行微动检测。为了产生该信号,瞳孔和角膜反射(CR)信号相互相减,并应用微分滤波器,两者都可以防止由于信号失真和噪声放大而检测到小的微跳。我们提出了一种新的算法,该算法直接从未校准的瞳孔和CR信号中检测微眼跳。它基于瞳孔和CR信号之间的去趋势,然后是窗相关。该算法优于该领域最常用的算法(Engbert & Kliegl, 2003),特别是对于即使用肉眼也难以在速度信号中看到的小幅度微跳。我们认为,在检测微小的微跳时,考虑眼动仪最基本的输出,即瞳孔和CR信号是有利的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Microsaccade detection using pupil and corneal reflection signals
In contemporary research, microsaccade detection is typically performed using the calibrated gaze-velocity signal acquired from a video-based eye tracker. To generate this signal, the pupil and corneal reflection (CR) signals are subtracted from each other and a differentiation filter is applied, both of which may prevent small microsaccades from being detected due to signal distortion and noise amplification. We propose a new algorithm where microsaccades are detected directly from uncalibrated pupil-, and CR signals. It is based on detrending followed by windowed correlation between pupil and CR signals. The proposed algorithm outperforms the most commonly used algorithm in the field (Engbert & Kliegl, 2003), in particular for small amplitude microsaccades that are difficult to see in the velocity signal even with the naked eye. We argue that it is advantageous to consider the most basic output of the eye tracker, i.e. pupil-, and CR signals, when detecting small microsaccades.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Evaluating gender difference on algorithmic problems using eye-tracker Eyemic Gaze patterns during remote presentations while listening and speaking An investigation of the effects of n-gram length in scanpath analysis for eye-tracking research Towards concise gaze sharing
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1