基于HHT的谐振接地系统单相接地故障特征分析

Yingwei Xiao, Hongbin Wu, Lin Zhang, B. Xiao
{"title":"基于HHT的谐振接地系统单相接地故障特征分析","authors":"Yingwei Xiao, Hongbin Wu, Lin Zhang, B. Xiao","doi":"10.1109/ICIEA.2016.7603834","DOIUrl":null,"url":null,"abstract":"Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in small current grounding system, HHT can be better used to extract the abundant transient time frequency information from the non-stationary and nonlinear fault current signals. The empirical mode decomposition (EMD) process and the normalized Hilbert Huang transform (NHHT) algorithm are presented, NHHT is used to analyze and verify an example of the nonlinear and non-stationary amplitude modulation signals. Build a small current grounding system in the EMTP_ATP environment, by selecting the appropriate time window to extract the transient signals, NHHT is used to analyze the transient current signals, and the Hilbert amplitude spectrum and the Hilbert marginal spectrum of the zero sequence transient current signals are obtained.","PeriodicalId":283114,"journal":{"name":"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Characteristic analysis of single-phase grounding fault in resonant grounded systems based-on HHT\",\"authors\":\"Yingwei Xiao, Hongbin Wu, Lin Zhang, B. Xiao\",\"doi\":\"10.1109/ICIEA.2016.7603834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in small current grounding system, HHT can be better used to extract the abundant transient time frequency information from the non-stationary and nonlinear fault current signals. The empirical mode decomposition (EMD) process and the normalized Hilbert Huang transform (NHHT) algorithm are presented, NHHT is used to analyze and verify an example of the nonlinear and non-stationary amplitude modulation signals. Build a small current grounding system in the EMTP_ATP environment, by selecting the appropriate time window to extract the transient signals, NHHT is used to analyze the transient current signals, and the Hilbert amplitude spectrum and the Hilbert marginal spectrum of the zero sequence transient current signals are obtained.\",\"PeriodicalId\":283114,\"journal\":{\"name\":\"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2016.7603834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2016.7603834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

对小电流接地系统单相接地故障进行了暂态分析,导出了暂态接地电流表达式,并对其影响因素进行了分析。介绍了一种非平稳非线性信号分析方法——希尔伯特黄变换(hilbert Huang transform, HHT)对小电流接地系统单相接地故障进行分析的方法,可以较好地利用HHT从非平稳非线性故障电流信号中提取丰富的暂态时频信息。提出了经验模态分解(EMD)方法和归一化Hilbert Huang变换(NHHT)算法,并利用该算法对一个非线性非平稳调幅信号进行了分析和验证。在EMTP_ATP环境下搭建小电流接地系统,通过选择合适的时间窗提取暂态信号,利用NHHT对暂态电流信号进行分析,得到零序暂态电流信号的Hilbert幅度谱和Hilbert边际谱。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Characteristic analysis of single-phase grounding fault in resonant grounded systems based-on HHT
Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in small current grounding system, HHT can be better used to extract the abundant transient time frequency information from the non-stationary and nonlinear fault current signals. The empirical mode decomposition (EMD) process and the normalized Hilbert Huang transform (NHHT) algorithm are presented, NHHT is used to analyze and verify an example of the nonlinear and non-stationary amplitude modulation signals. Build a small current grounding system in the EMTP_ATP environment, by selecting the appropriate time window to extract the transient signals, NHHT is used to analyze the transient current signals, and the Hilbert amplitude spectrum and the Hilbert marginal spectrum of the zero sequence transient current signals are obtained.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The electric power source structure optimization based on capital investment efficiency Modeling, control and implementation of high step-up ratio IDDB converters for fuel cell applications Research of heat transfer characteristic for PMSM with two-way ventilation structure Experimental researches on the novel single-phase induction motor Adaptive similarity fusion strategy in stereo matching algorithm
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1