{"title":"基于HHT的谐振接地系统单相接地故障特征分析","authors":"Yingwei Xiao, Hongbin Wu, Lin Zhang, B. Xiao","doi":"10.1109/ICIEA.2016.7603834","DOIUrl":null,"url":null,"abstract":"Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in small current grounding system, HHT can be better used to extract the abundant transient time frequency information from the non-stationary and nonlinear fault current signals. The empirical mode decomposition (EMD) process and the normalized Hilbert Huang transform (NHHT) algorithm are presented, NHHT is used to analyze and verify an example of the nonlinear and non-stationary amplitude modulation signals. Build a small current grounding system in the EMTP_ATP environment, by selecting the appropriate time window to extract the transient signals, NHHT is used to analyze the transient current signals, and the Hilbert amplitude spectrum and the Hilbert marginal spectrum of the zero sequence transient current signals are obtained.","PeriodicalId":283114,"journal":{"name":"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Characteristic analysis of single-phase grounding fault in resonant grounded systems based-on HHT\",\"authors\":\"Yingwei Xiao, Hongbin Wu, Lin Zhang, B. Xiao\",\"doi\":\"10.1109/ICIEA.2016.7603834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in small current grounding system, HHT can be better used to extract the abundant transient time frequency information from the non-stationary and nonlinear fault current signals. The empirical mode decomposition (EMD) process and the normalized Hilbert Huang transform (NHHT) algorithm are presented, NHHT is used to analyze and verify an example of the nonlinear and non-stationary amplitude modulation signals. Build a small current grounding system in the EMTP_ATP environment, by selecting the appropriate time window to extract the transient signals, NHHT is used to analyze the transient current signals, and the Hilbert amplitude spectrum and the Hilbert marginal spectrum of the zero sequence transient current signals are obtained.\",\"PeriodicalId\":283114,\"journal\":{\"name\":\"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIEA.2016.7603834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 11th Conference on Industrial Electronics and Applications (ICIEA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIEA.2016.7603834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Characteristic analysis of single-phase grounding fault in resonant grounded systems based-on HHT
Transient analysis is carried out for the single-phase grounding fault in small current grounding system, the transient grounding current expression is derived, and the influence factors are analyzed. Introduces a method for non-stationary and non-linear signal analysis method-Hilbert Huang transform (HHT) to analyze the single phase grounding fault in small current grounding system, HHT can be better used to extract the abundant transient time frequency information from the non-stationary and nonlinear fault current signals. The empirical mode decomposition (EMD) process and the normalized Hilbert Huang transform (NHHT) algorithm are presented, NHHT is used to analyze and verify an example of the nonlinear and non-stationary amplitude modulation signals. Build a small current grounding system in the EMTP_ATP environment, by selecting the appropriate time window to extract the transient signals, NHHT is used to analyze the transient current signals, and the Hilbert amplitude spectrum and the Hilbert marginal spectrum of the zero sequence transient current signals are obtained.