接地网的冲击响应:实验与模拟结果

M. Guimarães, L. Araújo, R. V. Castro, L. F. D. Santos, M. H. M. Vale, S. Visacro
{"title":"接地网的冲击响应:实验与模拟结果","authors":"M. Guimarães, L. Araújo, R. V. Castro, L. F. D. Santos, M. H. M. Vale, S. Visacro","doi":"10.1109/ICLP.2012.6344333","DOIUrl":null,"url":null,"abstract":"The experimental and simulated responses of a grounding grid, comprising 20 4-m-×-4-m meshes buried in a 160-Ωm soil, subjected to currents with lightning-patterned waveforms were determined. Simulations considered assumptions of constant and frequency dependent soil resistivity and permittivity. The amplitude and waveform of the measured and simulated grounding potential rise were quite similar and, due to the low value of soil resistivity, the frequency dependence of soil parameters practically did not affect the results.","PeriodicalId":400743,"journal":{"name":"2012 International Conference on Lightning Protection (ICLP)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Impulse response of grounding grids: Experimental versus simulated results\",\"authors\":\"M. Guimarães, L. Araújo, R. V. Castro, L. F. D. Santos, M. H. M. Vale, S. Visacro\",\"doi\":\"10.1109/ICLP.2012.6344333\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The experimental and simulated responses of a grounding grid, comprising 20 4-m-×-4-m meshes buried in a 160-Ωm soil, subjected to currents with lightning-patterned waveforms were determined. Simulations considered assumptions of constant and frequency dependent soil resistivity and permittivity. The amplitude and waveform of the measured and simulated grounding potential rise were quite similar and, due to the low value of soil resistivity, the frequency dependence of soil parameters practically did not affect the results.\",\"PeriodicalId\":400743,\"journal\":{\"name\":\"2012 International Conference on Lightning Protection (ICLP)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 International Conference on Lightning Protection (ICLP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICLP.2012.6344333\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 International Conference on Lightning Protection (ICLP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICLP.2012.6344333","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

实验和模拟了一个接地网的响应,该接地网由埋在160-Ωm土壤中的20个4-m-×-4-m网格组成,受到具有闪电波形的电流的影响。模拟考虑了恒定和频率相关的土壤电阻率和介电常数的假设。实测和模拟的接地电位上升幅度和波形非常相似,由于土壤电阻率值较低,土壤参数的频率依赖性实际上不影响结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impulse response of grounding grids: Experimental versus simulated results
The experimental and simulated responses of a grounding grid, comprising 20 4-m-×-4-m meshes buried in a 160-Ωm soil, subjected to currents with lightning-patterned waveforms were determined. Simulations considered assumptions of constant and frequency dependent soil resistivity and permittivity. The amplitude and waveform of the measured and simulated grounding potential rise were quite similar and, due to the low value of soil resistivity, the frequency dependence of soil parameters practically did not affect the results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Two unprecedented experiments to evaluate the effectiveness of lightning protection systems Investigations of earth termination systems with respect to optimised step voltages Estimation of the minimum shielding failure current causing flashover in overhead lines of the hellenic transmission system through ATP-EMTP simulations Calculating the Lightning Protection System downconductors' grounding resistance at Launch Complex 39B, Kennedy Space Center, Florida Factors influencing the selection and installation of surge protective devices for low voltage systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1