在放松管制的电力系统中,通过优化多因素装置的位置来增强ATC

B. Alekhya, J. Rao
{"title":"在放松管制的电力系统中,通过优化多因素装置的位置来增强ATC","authors":"B. Alekhya, J. Rao","doi":"10.1109/ISEG.2014.7005599","DOIUrl":null,"url":null,"abstract":"Increased electric power demand in a deregulated power system causes transmission lines to be driven beyond their transfer limits and causes violation of their limits which results to over load of lines. Available Transfer Capability (ATC) of a transmission system is a measure of unutilized capability of a system at a given time. The computation of ATC is very important to operate the transmission system more secure and the paper focuses on increasing the power transfer capability using FACTS devices like TCSC (Thyristor Controlled Series Capacitor), TCPAR (Thyristor Controlled Phase Angle Regulator), SVC (Static Var Compensator). These FACTS devices are optimally placed on transmission system using Sensitivity approach method. The proposed method is to enhance the ATC on Modified IEEE-14 bus system Using Power World Simulator 17software.","PeriodicalId":105826,"journal":{"name":"2014 International Conference on Smart Electric Grid (ISEG)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Enhancement of ATC in a deregulated power system by optimal location of multi-facts devices\",\"authors\":\"B. Alekhya, J. Rao\",\"doi\":\"10.1109/ISEG.2014.7005599\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Increased electric power demand in a deregulated power system causes transmission lines to be driven beyond their transfer limits and causes violation of their limits which results to over load of lines. Available Transfer Capability (ATC) of a transmission system is a measure of unutilized capability of a system at a given time. The computation of ATC is very important to operate the transmission system more secure and the paper focuses on increasing the power transfer capability using FACTS devices like TCSC (Thyristor Controlled Series Capacitor), TCPAR (Thyristor Controlled Phase Angle Regulator), SVC (Static Var Compensator). These FACTS devices are optimally placed on transmission system using Sensitivity approach method. The proposed method is to enhance the ATC on Modified IEEE-14 bus system Using Power World Simulator 17software.\",\"PeriodicalId\":105826,\"journal\":{\"name\":\"2014 International Conference on Smart Electric Grid (ISEG)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 International Conference on Smart Electric Grid (ISEG)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEG.2014.7005599\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 International Conference on Smart Electric Grid (ISEG)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEG.2014.7005599","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

在解除管制的电力系统中,电力需求的增加导致输电线路超出其传输限制,并导致违反其限制,从而导致线路过载。传输系统的可用传输能力(ATC)是对给定时间内系统未利用能力的度量。ATC的计算对于输电系统的安全运行非常重要,本文着重介绍了采用晶闸管控制串联电容器(TCSC)、晶闸管控制相角调节器(TCPAR)、静态无功补偿器(SVC)等FACTS器件来提高输电系统的功率传输能力。采用灵敏度法将这些FACTS器件优化放置在传输系统上。提出了一种利用Power World Simulator 17软件对改进型IEEE-14总线系统进行ATC增强的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Enhancement of ATC in a deregulated power system by optimal location of multi-facts devices
Increased electric power demand in a deregulated power system causes transmission lines to be driven beyond their transfer limits and causes violation of their limits which results to over load of lines. Available Transfer Capability (ATC) of a transmission system is a measure of unutilized capability of a system at a given time. The computation of ATC is very important to operate the transmission system more secure and the paper focuses on increasing the power transfer capability using FACTS devices like TCSC (Thyristor Controlled Series Capacitor), TCPAR (Thyristor Controlled Phase Angle Regulator), SVC (Static Var Compensator). These FACTS devices are optimally placed on transmission system using Sensitivity approach method. The proposed method is to enhance the ATC on Modified IEEE-14 bus system Using Power World Simulator 17software.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Improved outage prediction using asset management data and intelligent multiple interruption event handling with fuzzy control during extreme climatic conditions Application of multi agent system for distribution system automation Determination of appropriate location of superconducting fault current limiter in the smart grid Modelling and simulation of 14 bus system with TC-IPC Automatic generation control in power plant using PID, PSS and Fuzzy-PID controller
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1