{"title":"[低剂量区利用人牙釉质进行ESR剂量测定的问题]。","authors":"M Iwasaki, C Miyazawa, T Shimano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Experiments were made to determine the dependence of CO3(3-) signal intensity on radiation dose in the low dose region from 3.1 x 10(-4) C/kg to 865.6 x 10(-4) C/kg. After all human tooth enamel samples were crushed into 350-500 micrometers particles, they were irradiated with 60Co gamma rays. Irradiated samples were measured with the ESR instrument, and the CO3(3-) signal appearance and the true signal have been determined. It is confirmed that the relation between the true intensity of the CO3(3-) signal and the exposure have linearity from 25.0 x 10(-4) C/kg to 865.6 x 10(-4) C/kg. It is difficult to confirm this in the case of less than 25.0 x 10(-4) C/kg due to the effect of organic signal and noise.</p>","PeriodicalId":77585,"journal":{"name":"Ou Daigaku shigakushi","volume":"17 3","pages":"303-7"},"PeriodicalIF":0.0000,"publicationDate":"1990-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[A problem with ESR dosimetry utilizing human tooth enamel in low dose region].\",\"authors\":\"M Iwasaki, C Miyazawa, T Shimano\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Experiments were made to determine the dependence of CO3(3-) signal intensity on radiation dose in the low dose region from 3.1 x 10(-4) C/kg to 865.6 x 10(-4) C/kg. After all human tooth enamel samples were crushed into 350-500 micrometers particles, they were irradiated with 60Co gamma rays. Irradiated samples were measured with the ESR instrument, and the CO3(3-) signal appearance and the true signal have been determined. It is confirmed that the relation between the true intensity of the CO3(3-) signal and the exposure have linearity from 25.0 x 10(-4) C/kg to 865.6 x 10(-4) C/kg. It is difficult to confirm this in the case of less than 25.0 x 10(-4) C/kg due to the effect of organic signal and noise.</p>\",\"PeriodicalId\":77585,\"journal\":{\"name\":\"Ou Daigaku shigakushi\",\"volume\":\"17 3\",\"pages\":\"303-7\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ou Daigaku shigakushi\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ou Daigaku shigakushi","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[A problem with ESR dosimetry utilizing human tooth enamel in low dose region].
Experiments were made to determine the dependence of CO3(3-) signal intensity on radiation dose in the low dose region from 3.1 x 10(-4) C/kg to 865.6 x 10(-4) C/kg. After all human tooth enamel samples were crushed into 350-500 micrometers particles, they were irradiated with 60Co gamma rays. Irradiated samples were measured with the ESR instrument, and the CO3(3-) signal appearance and the true signal have been determined. It is confirmed that the relation between the true intensity of the CO3(3-) signal and the exposure have linearity from 25.0 x 10(-4) C/kg to 865.6 x 10(-4) C/kg. It is difficult to confirm this in the case of less than 25.0 x 10(-4) C/kg due to the effect of organic signal and noise.