A. Kadavelugu, H. Suryanarayana, Liming Liu, Zach Pan, Christopher Belcastro, Esa-Kai Paatero
{"title":"一种简单、准确的电源变换器效率测量方法","authors":"A. Kadavelugu, H. Suryanarayana, Liming Liu, Zach Pan, Christopher Belcastro, Esa-Kai Paatero","doi":"10.1109/APEC.2017.7931165","DOIUrl":null,"url":null,"abstract":"The accurate measurement of efficiency in wide band-gap semiconductor based converters, wherein efficiencies over 98% are achievable, is a challenge. In this work, a simple, open-loop, experimental dc-ac-dc back-to-back power conversion methodology is presented for the measurement of the combined losses of the power converter and passive filter. Additionally, only the power loss needs to be supplied by the source, although each converter sees active loading. The open-loop control mechanism for real and reactive power (power factor) control is explained, and also accuracy comparison with typical input and output power measurement method is provided. The simulation results of the proposed method are presented with experimental validation using a 1200 V SiC MOSFET based 4.6 kW — single phase (equivalent to 13.8 kW–3 phase) back-to-back conversion system.","PeriodicalId":201289,"journal":{"name":"2017 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"A simple and accurate efficiency measurement method for power converters\",\"authors\":\"A. Kadavelugu, H. Suryanarayana, Liming Liu, Zach Pan, Christopher Belcastro, Esa-Kai Paatero\",\"doi\":\"10.1109/APEC.2017.7931165\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The accurate measurement of efficiency in wide band-gap semiconductor based converters, wherein efficiencies over 98% are achievable, is a challenge. In this work, a simple, open-loop, experimental dc-ac-dc back-to-back power conversion methodology is presented for the measurement of the combined losses of the power converter and passive filter. Additionally, only the power loss needs to be supplied by the source, although each converter sees active loading. The open-loop control mechanism for real and reactive power (power factor) control is explained, and also accuracy comparison with typical input and output power measurement method is provided. The simulation results of the proposed method are presented with experimental validation using a 1200 V SiC MOSFET based 4.6 kW — single phase (equivalent to 13.8 kW–3 phase) back-to-back conversion system.\",\"PeriodicalId\":201289,\"journal\":{\"name\":\"2017 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2017.7931165\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2017.7931165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7
摘要
在基于宽带隙半导体的转换器中,效率可以达到98%以上,精确测量效率是一个挑战。在这项工作中,提出了一种简单的开环实验性dc-ac-dc背靠背功率转换方法,用于测量功率转换器和无源滤波器的综合损耗。此外,只有功率损失需要由源提供,尽管每个转换器都看到主动负载。阐述了实功率和无功功率(功率因数)控制的开环控制机理,并与典型的输入输出功率测量方法进行了精度比较。采用基于1200v SiC MOSFET的4.6 kW -单相(相当于13.8 kW - 3相)背对背转换系统,给出了该方法的仿真结果并进行了实验验证。
A simple and accurate efficiency measurement method for power converters
The accurate measurement of efficiency in wide band-gap semiconductor based converters, wherein efficiencies over 98% are achievable, is a challenge. In this work, a simple, open-loop, experimental dc-ac-dc back-to-back power conversion methodology is presented for the measurement of the combined losses of the power converter and passive filter. Additionally, only the power loss needs to be supplied by the source, although each converter sees active loading. The open-loop control mechanism for real and reactive power (power factor) control is explained, and also accuracy comparison with typical input and output power measurement method is provided. The simulation results of the proposed method are presented with experimental validation using a 1200 V SiC MOSFET based 4.6 kW — single phase (equivalent to 13.8 kW–3 phase) back-to-back conversion system.