新生儿听力测试声学耦合器的评价

B. Karaboce
{"title":"新生儿听力测试声学耦合器的评价","authors":"B. Karaboce","doi":"10.1109/MeMeA54994.2022.9856492","DOIUrl":null,"url":null,"abstract":"The acoustic coupler designed for newborn hearing assessments has been studied and used in in vitro tests. The acoustic transfer impedance (ATI) of the coupler was determined and compared with the theoretical model. In addition, its sensitivity to environmental conditions such as temperature and pressure was investigated at frequencies between 100 Hz and 10 kHz. Ear coupler has been compared with the IEC 60318–4 ear simulator and a 2 cm3 coupler and the results have been investigated. This paper reports on the results of experimental investigations for the new neonatal occluded ear simulator including in various atmospheric pressure and temperature conditions which was applied in automatic controlled environmental chambers. The uncertainty in the calibration is calculated in accordance with the methods specified in the “Guide to the Expression of Uncertainty in Measurement (GUM, ISO, 2nd edition, 1995)” and EA-4/02 (EA, 1999). A model function based on error has been created for the uncertainty calculations in the acoustic transfer impedance calculations and a detailed uncertainty budget has been given.","PeriodicalId":106228,"journal":{"name":"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Acoustic Coupler for Audiometric Tests of Newborns\",\"authors\":\"B. Karaboce\",\"doi\":\"10.1109/MeMeA54994.2022.9856492\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The acoustic coupler designed for newborn hearing assessments has been studied and used in in vitro tests. The acoustic transfer impedance (ATI) of the coupler was determined and compared with the theoretical model. In addition, its sensitivity to environmental conditions such as temperature and pressure was investigated at frequencies between 100 Hz and 10 kHz. Ear coupler has been compared with the IEC 60318–4 ear simulator and a 2 cm3 coupler and the results have been investigated. This paper reports on the results of experimental investigations for the new neonatal occluded ear simulator including in various atmospheric pressure and temperature conditions which was applied in automatic controlled environmental chambers. The uncertainty in the calibration is calculated in accordance with the methods specified in the “Guide to the Expression of Uncertainty in Measurement (GUM, ISO, 2nd edition, 1995)” and EA-4/02 (EA, 1999). A model function based on error has been created for the uncertainty calculations in the acoustic transfer impedance calculations and a detailed uncertainty budget has been given.\",\"PeriodicalId\":106228,\"journal\":{\"name\":\"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"36 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA54994.2022.9856492\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA54994.2022.9856492","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了用于新生儿听力评估的声学耦合器,并在体外试验中使用。测定了该耦合器的声传递阻抗,并与理论模型进行了比较。此外,在100 Hz和10 kHz之间的频率范围内,研究了其对温度和压力等环境条件的敏感性。将耳型耦合器与IEC 60318-4耳型模拟器和2 cm3的耳型耦合器进行了比较,并对结果进行了分析。本文报道了应用于自动控制环境室的新型新生儿闭塞耳模拟器在不同大气压和温度条件下的实验研究结果。校准中的不确定度按照“测量不确定度表达指南(GUM, ISO,第二版,1995)”和EA-4/02 (EA, 1999)中规定的方法计算。针对声传递阻抗计算中的不确定性计算,建立了基于误差的模型函数,并给出了详细的不确定性预算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of Acoustic Coupler for Audiometric Tests of Newborns
The acoustic coupler designed for newborn hearing assessments has been studied and used in in vitro tests. The acoustic transfer impedance (ATI) of the coupler was determined and compared with the theoretical model. In addition, its sensitivity to environmental conditions such as temperature and pressure was investigated at frequencies between 100 Hz and 10 kHz. Ear coupler has been compared with the IEC 60318–4 ear simulator and a 2 cm3 coupler and the results have been investigated. This paper reports on the results of experimental investigations for the new neonatal occluded ear simulator including in various atmospheric pressure and temperature conditions which was applied in automatic controlled environmental chambers. The uncertainty in the calibration is calculated in accordance with the methods specified in the “Guide to the Expression of Uncertainty in Measurement (GUM, ISO, 2nd edition, 1995)” and EA-4/02 (EA, 1999). A model function based on error has been created for the uncertainty calculations in the acoustic transfer impedance calculations and a detailed uncertainty budget has been given.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Time and Frequency domain analysis of APB muscles Abduction in adult dominant hand using surface electromyography signals Comparison of Noise Reduction Techniques for Dysarthric Speech Recognition Effects of ROI positioning on the measurement of engineered muscle tissue contractility with an optical tracking method Atrial Fibrillation Detection by Means of Edge Computing on Wearable Device: A Feasibility Assessment Unraveling the biological meaning of radiomic features
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1