{"title":"特高压输电线路快速定向比较导频保护","authors":"Yueyang Ma, G. Zou, Zhanjun Gao, Tao Du","doi":"10.1109/APPEEC.2016.7779559","DOIUrl":null,"url":null,"abstract":"This paper proposes a new pilot protection method for ultra-high voltage (UHV) transmission line, which is based on the characteristics of the average value of the fault component current. Theoretic analysis shows for an internal fault, the signs of the average values of the fault component current detected by relays on both ends of the line are identical, while they are opposite for an external fault. Through comparing the signs of the average values detected by two relays on both ends of the line, an internal fault can be distinguished from an external fault. Using PSCAD software, a 1000 kV transmission line model was constructed, and extensive simulations were performed. The simulation results indicate the validity and feasibility of the proposed protection method.","PeriodicalId":117485,"journal":{"name":"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","volume":"213 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A fast directional comparison pilot protection for UHV transmission line\",\"authors\":\"Yueyang Ma, G. Zou, Zhanjun Gao, Tao Du\",\"doi\":\"10.1109/APPEEC.2016.7779559\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a new pilot protection method for ultra-high voltage (UHV) transmission line, which is based on the characteristics of the average value of the fault component current. Theoretic analysis shows for an internal fault, the signs of the average values of the fault component current detected by relays on both ends of the line are identical, while they are opposite for an external fault. Through comparing the signs of the average values detected by two relays on both ends of the line, an internal fault can be distinguished from an external fault. Using PSCAD software, a 1000 kV transmission line model was constructed, and extensive simulations were performed. The simulation results indicate the validity and feasibility of the proposed protection method.\",\"PeriodicalId\":117485,\"journal\":{\"name\":\"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"volume\":\"213 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APPEEC.2016.7779559\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE PES Asia-Pacific Power and Energy Engineering Conference (APPEEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APPEEC.2016.7779559","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种基于故障分量电流平均值特征的特高压输电线路导频保护新方法。理论分析表明,对于内部故障,线路两端继电器检测到的故障分量电流平均值的符号是相同的,而对于外部故障,则相反。通过比较线路两端的两个继电器检测到的平均值的符号,可以区分内部故障和外部故障。利用PSCAD软件建立了1000 kV输电线路模型,并进行了大量的仿真。仿真结果表明了所提保护方法的有效性和可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A fast directional comparison pilot protection for UHV transmission line
This paper proposes a new pilot protection method for ultra-high voltage (UHV) transmission line, which is based on the characteristics of the average value of the fault component current. Theoretic analysis shows for an internal fault, the signs of the average values of the fault component current detected by relays on both ends of the line are identical, while they are opposite for an external fault. Through comparing the signs of the average values detected by two relays on both ends of the line, an internal fault can be distinguished from an external fault. Using PSCAD software, a 1000 kV transmission line model was constructed, and extensive simulations were performed. The simulation results indicate the validity and feasibility of the proposed protection method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Electric Vehicle charging management algorithm for a UK low-voltage residential distribution network An optimization model of EVs charging and discharging for power system demand leveling A circuit approach for the propagation analysis of voltage unbalance emission in power systems A novel high-power AC/AC modular multilevel converter in Y configuration and its control strategy Comprehensive optimization for power system with multiple HVDC infeed
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1