{"title":"双馈感应电机在超同步模式下电压凹陷的影响","authors":"Navneet Kumar, T. Chelliah, S. P. Srivastava","doi":"10.1109/CIPECH.2014.7019041","DOIUrl":null,"url":null,"abstract":"Load-frequency match is mandatory requirement for interconnected power system stability. Any unscheduled change in load or intermittent power injection from Renewable Energy Sources (RES) leads to system instability by changing the frequency. Therefore, energy storage devices are essential as they can provide quick response for any change in system frequency. Pumped Storage Plants (PSP) serves the dual purpose, either by storing surplus power or by generating hydro power during peak requirements. The use of Doubly-Fed Induction Machine (DFIM) with power electronics in rotor circuit is significant in both motoring and generating modes in PSP. This paper investigates the effect of symmetrical voltage sag on the performance of DFIM at motoring mode. Various motor parameters, namely peaks in total power taken from grid, torque and current (stator and rotor current), and speed loss were investigated. With the aid of both simulation and experimental results, symmetrical voltage sag effects on a 2.2kW three-phase DFIM are analyzed. In steady-state operation of DFIM, the voltage sag produces motor instability which depends on sag depth and duration.","PeriodicalId":170027,"journal":{"name":"2014 Innovative Applications of Computational Intelligence on Power, Energy and Controls with their impact on Humanity (CIPECH)","volume":"59 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of voltage sag on Doubly fed induction machine at hyper-synchronous motoring mode\",\"authors\":\"Navneet Kumar, T. Chelliah, S. P. Srivastava\",\"doi\":\"10.1109/CIPECH.2014.7019041\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Load-frequency match is mandatory requirement for interconnected power system stability. Any unscheduled change in load or intermittent power injection from Renewable Energy Sources (RES) leads to system instability by changing the frequency. Therefore, energy storage devices are essential as they can provide quick response for any change in system frequency. Pumped Storage Plants (PSP) serves the dual purpose, either by storing surplus power or by generating hydro power during peak requirements. The use of Doubly-Fed Induction Machine (DFIM) with power electronics in rotor circuit is significant in both motoring and generating modes in PSP. This paper investigates the effect of symmetrical voltage sag on the performance of DFIM at motoring mode. Various motor parameters, namely peaks in total power taken from grid, torque and current (stator and rotor current), and speed loss were investigated. With the aid of both simulation and experimental results, symmetrical voltage sag effects on a 2.2kW three-phase DFIM are analyzed. In steady-state operation of DFIM, the voltage sag produces motor instability which depends on sag depth and duration.\",\"PeriodicalId\":170027,\"journal\":{\"name\":\"2014 Innovative Applications of Computational Intelligence on Power, Energy and Controls with their impact on Humanity (CIPECH)\",\"volume\":\"59 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 Innovative Applications of Computational Intelligence on Power, Energy and Controls with their impact on Humanity (CIPECH)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIPECH.2014.7019041\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 Innovative Applications of Computational Intelligence on Power, Energy and Controls with their impact on Humanity (CIPECH)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIPECH.2014.7019041","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

负荷-频率匹配是保证互联电力系统稳定运行的必然要求。负荷的任何计划外变化或可再生能源(RES)的间歇性电力注入都会通过改变频率导致系统不稳定。因此,储能装置是必不可少的,因为它们可以对系统频率的任何变化提供快速响应。抽水蓄能电站(PSP)具有双重用途,要么储存剩余电力,要么在高峰需求时发电。在转子电路中使用双馈感应电机(DFIM)与电力电子器件在PSP的驱动和发电模式中都具有重要意义。本文研究了对称电压暂降对DFIM在运动模式下性能的影响。研究了电机的各种参数,即从电网获取的总功率峰值、转矩和电流(定子和转子电流)以及转速损失。结合仿真和实验结果,分析了2.2kW三相DFIM的对称电压暂降效应。在DFIM稳态运行中,电压暂降引起电机失稳,其失稳程度与暂降的持续时间有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effects of voltage sag on Doubly fed induction machine at hyper-synchronous motoring mode
Load-frequency match is mandatory requirement for interconnected power system stability. Any unscheduled change in load or intermittent power injection from Renewable Energy Sources (RES) leads to system instability by changing the frequency. Therefore, energy storage devices are essential as they can provide quick response for any change in system frequency. Pumped Storage Plants (PSP) serves the dual purpose, either by storing surplus power or by generating hydro power during peak requirements. The use of Doubly-Fed Induction Machine (DFIM) with power electronics in rotor circuit is significant in both motoring and generating modes in PSP. This paper investigates the effect of symmetrical voltage sag on the performance of DFIM at motoring mode. Various motor parameters, namely peaks in total power taken from grid, torque and current (stator and rotor current), and speed loss were investigated. With the aid of both simulation and experimental results, symmetrical voltage sag effects on a 2.2kW three-phase DFIM are analyzed. In steady-state operation of DFIM, the voltage sag produces motor instability which depends on sag depth and duration.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Hybrid CMOS-memristor 4T-NVSRAM cell for low power applications VLSI architecture and implementation of statistical multiplexer A comparative analysis of ant colony optimization for its applications into software testing Neurofuzzy inference system for diagnosis of Leukemia Computation & analysis of aluminum and steel structures by using ABAQUS software for engineering applications
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1