You-Kuang Chang, Chao-Shiun Wang, Chorng-Kuang Wang
{"title":"用于生物医学应用的8位500-KS/s低功耗SAR ADC","authors":"You-Kuang Chang, Chao-Shiun Wang, Chorng-Kuang Wang","doi":"10.1109/ASSCC.2007.4425772","DOIUrl":null,"url":null,"abstract":"This paper presents a successive approximation register analog-to-digital converter (SAR ADC) design for bio-medical applications. An energy-saving switching sequence technique is proposed to achieve low power consumption. The average switching energy of the capacitor array can be reduced by 56% compared to a conventional switching method. The measured signal-to-noise-and-distortion ratios of the ADC is 46.92 dB at 500 KS/s sampling rate with an ultra-low power consumption of only 7.75-muW from a 1-V supply voltage. The ADC is fabricated in a 0.18-mum CMOS technology.","PeriodicalId":186095,"journal":{"name":"2007 IEEE Asian Solid-State Circuits Conference","volume":"39 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2007-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"169","resultStr":"{\"title\":\"A 8-bit 500-KS/s low power SAR ADC for bio-medical applications\",\"authors\":\"You-Kuang Chang, Chao-Shiun Wang, Chorng-Kuang Wang\",\"doi\":\"10.1109/ASSCC.2007.4425772\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a successive approximation register analog-to-digital converter (SAR ADC) design for bio-medical applications. An energy-saving switching sequence technique is proposed to achieve low power consumption. The average switching energy of the capacitor array can be reduced by 56% compared to a conventional switching method. The measured signal-to-noise-and-distortion ratios of the ADC is 46.92 dB at 500 KS/s sampling rate with an ultra-low power consumption of only 7.75-muW from a 1-V supply voltage. The ADC is fabricated in a 0.18-mum CMOS technology.\",\"PeriodicalId\":186095,\"journal\":{\"name\":\"2007 IEEE Asian Solid-State Circuits Conference\",\"volume\":\"39 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"169\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2007 IEEE Asian Solid-State Circuits Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2007.4425772\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2007 IEEE Asian Solid-State Circuits Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2007.4425772","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 169
摘要
提出了一种用于生物医学应用的逐次逼近寄存器模数转换器(SAR ADC)设计。为了实现低功耗,提出了一种节能开关顺序技术。与传统的开关方法相比,该电容器阵列的平均开关能量可降低56%。在500 KS/s采样率下,ADC的信噪比和失真比为46.92 dB,在1 v电源电压下,功耗仅为7.75 muw。该ADC采用0.18 μ m CMOS技术制造。
A 8-bit 500-KS/s low power SAR ADC for bio-medical applications
This paper presents a successive approximation register analog-to-digital converter (SAR ADC) design for bio-medical applications. An energy-saving switching sequence technique is proposed to achieve low power consumption. The average switching energy of the capacitor array can be reduced by 56% compared to a conventional switching method. The measured signal-to-noise-and-distortion ratios of the ADC is 46.92 dB at 500 KS/s sampling rate with an ultra-low power consumption of only 7.75-muW from a 1-V supply voltage. The ADC is fabricated in a 0.18-mum CMOS technology.