{"title":"某硫磺厂余热锅炉管板接头硫化速率预测","authors":"F. Ju, Allen Miller, Simon Yuen, Brian Tkachyk","doi":"10.1115/PVP2018-85070","DOIUrl":null,"url":null,"abstract":"Sulfidation corrosion of the carbon steel tubes at the tube-to-tubesheet joint often governs the life of waste heat boilers in sulphur recovery plants. Conventional tube joints typically have a welded joint located at the hot-side face of the tubesheet. An alternative design involves welding the tubesheet joint at the cold-side face of the tubesheet, close to the boiler feed water. The alternative design also employs stainless steel cladding on the tubesheet face and a tube-hole sleeve selectively at high-temperature locations. Finite element heat transfer analysis is used to establish the thermal profiles of the conventional and the alternative designs. From the worked example, the alternative design provided a lower metal temperature by approximately 80 °F at the joint, as compared to the conventional tube joint. Sulfidation rate prediction based on a sample gas composition using ASSET (Alloy Selection System for Elevated Temperatures) Software predicts that the alternative design can reduce the sulfidation rate by 35% because of the lower metal temperature.","PeriodicalId":384066,"journal":{"name":"Volume 3B: Design and Analysis","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2018-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sulfidation Rate Prediction on Tube-to-Tubesheet Joints in a Waste Heat Boiler in a Sulphur Plant\",\"authors\":\"F. Ju, Allen Miller, Simon Yuen, Brian Tkachyk\",\"doi\":\"10.1115/PVP2018-85070\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sulfidation corrosion of the carbon steel tubes at the tube-to-tubesheet joint often governs the life of waste heat boilers in sulphur recovery plants. Conventional tube joints typically have a welded joint located at the hot-side face of the tubesheet. An alternative design involves welding the tubesheet joint at the cold-side face of the tubesheet, close to the boiler feed water. The alternative design also employs stainless steel cladding on the tubesheet face and a tube-hole sleeve selectively at high-temperature locations. Finite element heat transfer analysis is used to establish the thermal profiles of the conventional and the alternative designs. From the worked example, the alternative design provided a lower metal temperature by approximately 80 °F at the joint, as compared to the conventional tube joint. Sulfidation rate prediction based on a sample gas composition using ASSET (Alloy Selection System for Elevated Temperatures) Software predicts that the alternative design can reduce the sulfidation rate by 35% because of the lower metal temperature.\",\"PeriodicalId\":384066,\"journal\":{\"name\":\"Volume 3B: Design and Analysis\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Volume 3B: Design and Analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1115/PVP2018-85070\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Volume 3B: Design and Analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/PVP2018-85070","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Sulfidation Rate Prediction on Tube-to-Tubesheet Joints in a Waste Heat Boiler in a Sulphur Plant
Sulfidation corrosion of the carbon steel tubes at the tube-to-tubesheet joint often governs the life of waste heat boilers in sulphur recovery plants. Conventional tube joints typically have a welded joint located at the hot-side face of the tubesheet. An alternative design involves welding the tubesheet joint at the cold-side face of the tubesheet, close to the boiler feed water. The alternative design also employs stainless steel cladding on the tubesheet face and a tube-hole sleeve selectively at high-temperature locations. Finite element heat transfer analysis is used to establish the thermal profiles of the conventional and the alternative designs. From the worked example, the alternative design provided a lower metal temperature by approximately 80 °F at the joint, as compared to the conventional tube joint. Sulfidation rate prediction based on a sample gas composition using ASSET (Alloy Selection System for Elevated Temperatures) Software predicts that the alternative design can reduce the sulfidation rate by 35% because of the lower metal temperature.