引风机冷却塔控制参数的反演方法

R. Singla, R. Das
{"title":"引风机冷却塔控制参数的反演方法","authors":"R. Singla, R. Das","doi":"10.1109/CCSSE.2016.7784386","DOIUrl":null,"url":null,"abstract":"In this work, application of the Golden Section Search Method (GSSM) is illustrated to inversely retrieve the controlling parameter meeting a desired performance requirement in an induced draft cooling tower. Merkel number is an important performance parameter because it involves various parameters such as global heat and mass transfer coefficient, water flow rate, dimensions (interfacial area per unit volume) and range within itself. At first, experiments have been performed to get accurate correlations for Merkel number against the controlling parameter that is required to be estimated, which is the air mass flow rate. Then, an inverse optimization technique involving GSSM has been used to estimate the required air flow rate in order to satisfy a given performance parameter. It is found from the present study that the controlling parameter estimated using GSSM yields a very good reconstruction of the Merkel number.","PeriodicalId":136809,"journal":{"name":"2016 2nd International Conference on Control Science and Systems Engineering (ICCSSE)","volume":"13 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Retrieval of controlling parameter in induced draft cooling tower using inverse method\",\"authors\":\"R. Singla, R. Das\",\"doi\":\"10.1109/CCSSE.2016.7784386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, application of the Golden Section Search Method (GSSM) is illustrated to inversely retrieve the controlling parameter meeting a desired performance requirement in an induced draft cooling tower. Merkel number is an important performance parameter because it involves various parameters such as global heat and mass transfer coefficient, water flow rate, dimensions (interfacial area per unit volume) and range within itself. At first, experiments have been performed to get accurate correlations for Merkel number against the controlling parameter that is required to be estimated, which is the air mass flow rate. Then, an inverse optimization technique involving GSSM has been used to estimate the required air flow rate in order to satisfy a given performance parameter. It is found from the present study that the controlling parameter estimated using GSSM yields a very good reconstruction of the Merkel number.\",\"PeriodicalId\":136809,\"journal\":{\"name\":\"2016 2nd International Conference on Control Science and Systems Engineering (ICCSSE)\",\"volume\":\"13 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 2nd International Conference on Control Science and Systems Engineering (ICCSSE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CCSSE.2016.7784386\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 2nd International Conference on Control Science and Systems Engineering (ICCSSE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CCSSE.2016.7784386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在本工作中,应用黄金分割搜索法(GSSM)逆检索控制参数满足诱导通风冷却塔的预期性能要求。默克尔数是一个重要的性能参数,因为它涉及到各种参数,如整体传热传质系数、水流速率、尺寸(单位体积的界面面积)和自身范围。首先,进行了实验,以获得默克尔数与需要估计的控制参数(即空气质量流量)的精确相关性。然后,利用GSSM的逆优化技术估计满足给定性能参数所需的空气流量。从本研究中发现,使用GSSM估计的控制参数产生了非常好的默克尔数重建。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Retrieval of controlling parameter in induced draft cooling tower using inverse method
In this work, application of the Golden Section Search Method (GSSM) is illustrated to inversely retrieve the controlling parameter meeting a desired performance requirement in an induced draft cooling tower. Merkel number is an important performance parameter because it involves various parameters such as global heat and mass transfer coefficient, water flow rate, dimensions (interfacial area per unit volume) and range within itself. At first, experiments have been performed to get accurate correlations for Merkel number against the controlling parameter that is required to be estimated, which is the air mass flow rate. Then, an inverse optimization technique involving GSSM has been used to estimate the required air flow rate in order to satisfy a given performance parameter. It is found from the present study that the controlling parameter estimated using GSSM yields a very good reconstruction of the Merkel number.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Fuzzy logic controller design for intelligent air-conditioning system Design of multi-point wireless multifunction monitoring system based on Android Link weights-based ANT colony routing algorithm for wireless sensor networks Study on control method of activated sludge sewage treatment system Adaptive sliding mode control for a vehicle steer-by-wire system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1