脉冲电流测量系统的标定研究

Yuan Yuan, Feng Jianqiang, Jiang Ning, Jia Zhuanzhuan, Li He
{"title":"脉冲电流测量系统的标定研究","authors":"Yuan Yuan, Feng Jianqiang, Jiang Ning, Jia Zhuanzhuan, Li He","doi":"10.1109/ICEMI.2017.8265978","DOIUrl":null,"url":null,"abstract":"The calibration of the impulse current measurement system has been clearly stipulated in the standard GB/T 16927.4-2014, With the implementation of GB/T 16927.4-2014. In order to promote the standardization of the calibration system, this paper analyzes the impulse current measurement system architecture, Analysis of the impulse current measurement system scale factor calibration methods and the uncertainty calculation of time-parameter measurements. Then, each test example was executed. The uncertainty of under calibration impulse current measurement system was evaluation, For the implementation of standard provides the beneficial practice and guidance.","PeriodicalId":275568,"journal":{"name":"2017 13th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Study on calibration of impulse current measuring system\",\"authors\":\"Yuan Yuan, Feng Jianqiang, Jiang Ning, Jia Zhuanzhuan, Li He\",\"doi\":\"10.1109/ICEMI.2017.8265978\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The calibration of the impulse current measurement system has been clearly stipulated in the standard GB/T 16927.4-2014, With the implementation of GB/T 16927.4-2014. In order to promote the standardization of the calibration system, this paper analyzes the impulse current measurement system architecture, Analysis of the impulse current measurement system scale factor calibration methods and the uncertainty calculation of time-parameter measurements. Then, each test example was executed. The uncertainty of under calibration impulse current measurement system was evaluation, For the implementation of standard provides the beneficial practice and guidance.\",\"PeriodicalId\":275568,\"journal\":{\"name\":\"2017 13th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 13th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMI.2017.8265978\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 13th IEEE International Conference on Electronic Measurement & Instruments (ICEMI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMI.2017.8265978","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

冲击电流测量系统的标定在标准GB/T 16927.4-2014中有明确规定,现实施GB/T 16927.4-2014。为了促进校准系统的标准化,本文分析了冲击电流测量系统的结构,分析了冲击电流测量系统尺度因子的校准方法和时间参数测量的不确定度计算。然后,执行每个测试示例。对未标定脉冲电流测量系统的不确定度进行了评定,为标准的实施提供了有益的实践和指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Study on calibration of impulse current measuring system
The calibration of the impulse current measurement system has been clearly stipulated in the standard GB/T 16927.4-2014, With the implementation of GB/T 16927.4-2014. In order to promote the standardization of the calibration system, this paper analyzes the impulse current measurement system architecture, Analysis of the impulse current measurement system scale factor calibration methods and the uncertainty calculation of time-parameter measurements. Then, each test example was executed. The uncertainty of under calibration impulse current measurement system was evaluation, For the implementation of standard provides the beneficial practice and guidance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Novel algorithm of channel estimation for CP-OFDM systems with pilot symbols in frequency domain Power spectral density estimation from random interleaved samples Application of adaptive median filter and wavelet transform to dongba manuscript images denoising Atomic clock frequency difference prediction algorithm based on genetic wavelet neural network Particle velocity measurement using linear capacitive sensor matrix
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1