钩位对假手中指应力和位移的数值分析

G. P. Annanto, R. Ismail, I. Haryanto, M. Ariyanto, K. A. Pambudi
{"title":"钩位对假手中指应力和位移的数值分析","authors":"G. P. Annanto, R. Ismail, I. Haryanto, M. Ariyanto, K. A. Pambudi","doi":"10.1109/IBITeC46597.2019.9091681","DOIUrl":null,"url":null,"abstract":"Upper limb disabilities become a concern to Indonesia. There are many prosthetic hand products from other countries, but they do not fit to Indonesian citizen, neither for the price nor the size. Because of it, Diponegoro University developed a prosthetic hand to solve the problem that currently faced by the Indonesian citizen. This prosthetic hand was expected to be a prosthetic hand that fit, either for the price or the size, with Indonesian citizen. Design safety becomes the concern of the development of prosthetic hand, and this paper investigates the reliability of the Middle finger of the prosthetic hand under the hook load. The result is the upper part experienced maximum stress at the value 54.524MPa and the lower part experienced maximum stress at the value 29.472 MPa. The maximum stress that occurs on the Middle finger of the prosthetic hand was still under the yield stress of material. With the safety factor about 1.28 and 2.37 for upper part and lower part, respectively, it can be considered that the prosthetic hand that has been developed in Diponegoro University was safe to use on hook position","PeriodicalId":198107,"journal":{"name":"2019 International Biomedical Instrumentation and Technology Conference (IBITeC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical Analysis of Stress and Displacement on The Middle Finger of The Prosthetic Hand Due to Hook Position\",\"authors\":\"G. P. Annanto, R. Ismail, I. Haryanto, M. Ariyanto, K. A. Pambudi\",\"doi\":\"10.1109/IBITeC46597.2019.9091681\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Upper limb disabilities become a concern to Indonesia. There are many prosthetic hand products from other countries, but they do not fit to Indonesian citizen, neither for the price nor the size. Because of it, Diponegoro University developed a prosthetic hand to solve the problem that currently faced by the Indonesian citizen. This prosthetic hand was expected to be a prosthetic hand that fit, either for the price or the size, with Indonesian citizen. Design safety becomes the concern of the development of prosthetic hand, and this paper investigates the reliability of the Middle finger of the prosthetic hand under the hook load. The result is the upper part experienced maximum stress at the value 54.524MPa and the lower part experienced maximum stress at the value 29.472 MPa. The maximum stress that occurs on the Middle finger of the prosthetic hand was still under the yield stress of material. With the safety factor about 1.28 and 2.37 for upper part and lower part, respectively, it can be considered that the prosthetic hand that has been developed in Diponegoro University was safe to use on hook position\",\"PeriodicalId\":198107,\"journal\":{\"name\":\"2019 International Biomedical Instrumentation and Technology Conference (IBITeC)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 International Biomedical Instrumentation and Technology Conference (IBITeC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IBITeC46597.2019.9091681\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 International Biomedical Instrumentation and Technology Conference (IBITeC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IBITeC46597.2019.9091681","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

上肢残疾成为印度尼西亚关注的问题。其他国家有很多假手产品,但无论是价格还是尺寸都不适合印尼公民。正因为如此,迪波尼戈罗大学开发了一种假手来解决印尼公民目前面临的问题。这只假手应该是一只适合印尼公民的假手,无论是价格还是尺寸。设计安全性成为假手发展的重点,本文对假手中指在钩载荷作用下的可靠性进行了研究。结果表明:上部最大应力值为54.524MPa,下部最大应力值为29.472 MPa。假手中指所受的最大应力仍在材料屈服应力下。由于上肢和下肢的安全系数分别约为1.28和2.37,因此可以认为Diponegoro大学开发的假手在钩位上使用是安全的
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical Analysis of Stress and Displacement on The Middle Finger of The Prosthetic Hand Due to Hook Position
Upper limb disabilities become a concern to Indonesia. There are many prosthetic hand products from other countries, but they do not fit to Indonesian citizen, neither for the price nor the size. Because of it, Diponegoro University developed a prosthetic hand to solve the problem that currently faced by the Indonesian citizen. This prosthetic hand was expected to be a prosthetic hand that fit, either for the price or the size, with Indonesian citizen. Design safety becomes the concern of the development of prosthetic hand, and this paper investigates the reliability of the Middle finger of the prosthetic hand under the hook load. The result is the upper part experienced maximum stress at the value 54.524MPa and the lower part experienced maximum stress at the value 29.472 MPa. The maximum stress that occurs on the Middle finger of the prosthetic hand was still under the yield stress of material. With the safety factor about 1.28 and 2.37 for upper part and lower part, respectively, it can be considered that the prosthetic hand that has been developed in Diponegoro University was safe to use on hook position
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Optimization of Mechanical Parameters on Outsole Shoes Orthotic Comfort Using Finite Element Analysis Performance Comparison of Linear and Non Linear Interference Cancellation Techniques for 3.466 Gbps WLAN Multifractal detrended fluctuation analysis of heart rate variability predicts short-term outcomes of patients with sepsis 3D Image Reconstruction with Single-Slice CT using Improved Marching Cube Algorithm Performance Evaluation of Ensembles Algorithms in Prediction of Breast Cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1