风能和太阳能联合分布式发电机组的模糊系统控制

H. Weiss, J. Xiao
{"title":"风能和太阳能联合分布式发电机组的模糊系统控制","authors":"H. Weiss, J. Xiao","doi":"10.1109/ICIT.2003.1290828","DOIUrl":null,"url":null,"abstract":"For renewable energy generation in the distributed and co-generation (DCG) scheme, photovoltaics and wind power are already in service at many installations. Basically, these types of energy generation are very favourable for the environment but do not produce power on customers load demands, have long intervals of lacking power generation due to absence of power input (no sunshine, no wind), and especially exhibit high costs per installed power respectively per generated energy. So every cost saving and output increasing measure should be taken. Combining a photovoltaic power unit with a wind energy unit will reduce the zero-power intervals and can be composed to high extent of standard commercial variable speed drive elements. These are PWM voltage source inverters with active front end, and also standard induction machines can be taken. Only a few extensions are necessary, thus the total hardware system is rather cost effective. It is essential that a system control unit defines setpoint values for the sub-units and handles abnormal operating conditions. Here a fuzzy control system is proposed to accomplish these tasks. It means performing the standard power insertion into the line on the principle of maximum power tracking, preferable at a rather constant power input without flicker power, ensuring or improving line voltage quality with regard to reactive power and distortion power, or voltage waveform improvement, respectively. In addition, in case of a line interruption, the unit should be able to run independently from the line, establishing an insular power supply for the nearby customers and loads until the reconnection to the mains is done.","PeriodicalId":193510,"journal":{"name":"IEEE International Conference on Industrial Technology, 2003","volume":"113 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":"{\"title\":\"Fuzzy system control for combined wind and solar power distributed generation unit\",\"authors\":\"H. Weiss, J. Xiao\",\"doi\":\"10.1109/ICIT.2003.1290828\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For renewable energy generation in the distributed and co-generation (DCG) scheme, photovoltaics and wind power are already in service at many installations. Basically, these types of energy generation are very favourable for the environment but do not produce power on customers load demands, have long intervals of lacking power generation due to absence of power input (no sunshine, no wind), and especially exhibit high costs per installed power respectively per generated energy. So every cost saving and output increasing measure should be taken. Combining a photovoltaic power unit with a wind energy unit will reduce the zero-power intervals and can be composed to high extent of standard commercial variable speed drive elements. These are PWM voltage source inverters with active front end, and also standard induction machines can be taken. Only a few extensions are necessary, thus the total hardware system is rather cost effective. It is essential that a system control unit defines setpoint values for the sub-units and handles abnormal operating conditions. Here a fuzzy control system is proposed to accomplish these tasks. It means performing the standard power insertion into the line on the principle of maximum power tracking, preferable at a rather constant power input without flicker power, ensuring or improving line voltage quality with regard to reactive power and distortion power, or voltage waveform improvement, respectively. In addition, in case of a line interruption, the unit should be able to run independently from the line, establishing an insular power supply for the nearby customers and loads until the reconnection to the mains is done.\",\"PeriodicalId\":193510,\"journal\":{\"name\":\"IEEE International Conference on Industrial Technology, 2003\",\"volume\":\"113 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-12-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"11\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE International Conference on Industrial Technology, 2003\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIT.2003.1290828\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Conference on Industrial Technology, 2003","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIT.2003.1290828","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

摘要

对于分布式和热电联产(DCG)计划中的可再生能源发电,光伏和风力发电已经在许多设施中投入使用。基本上,这些类型的能源发电对环境非常有利,但不能满足客户的负载需求,由于缺乏电力输入(没有阳光,没有风),缺乏发电的时间间隔很长,特别是每发电一次的装机成本很高。因此,必须采取各种节约成本和提高产量的措施。光伏发电机组与风力发电机组的组合将缩短零功率间隔,并可在很大程度上组成标准的商用变速驱动元件。这些是具有主动前端的PWM电压源逆变器,也可以采用标准感应电机。只需要几个扩展,因此整个硬件系统的成本效益相当高。重要的是,系统控制单元为子单元定义设定值并处理异常操作条件。本文提出了一种模糊控制系统来完成这些任务。它是指按照最大功率跟踪的原则对线路进行标准的电源插入,最好是在一个相当恒定的功率输入,没有闪烁功率,保证或改善线路电压质量,即无功功率和失真功率,或改善电压波形。此外,在线路中断的情况下,机组应该能够独立于线路运行,为附近的客户和负载建立一个孤立的电源供应,直到重新连接到主电源完成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Fuzzy system control for combined wind and solar power distributed generation unit
For renewable energy generation in the distributed and co-generation (DCG) scheme, photovoltaics and wind power are already in service at many installations. Basically, these types of energy generation are very favourable for the environment but do not produce power on customers load demands, have long intervals of lacking power generation due to absence of power input (no sunshine, no wind), and especially exhibit high costs per installed power respectively per generated energy. So every cost saving and output increasing measure should be taken. Combining a photovoltaic power unit with a wind energy unit will reduce the zero-power intervals and can be composed to high extent of standard commercial variable speed drive elements. These are PWM voltage source inverters with active front end, and also standard induction machines can be taken. Only a few extensions are necessary, thus the total hardware system is rather cost effective. It is essential that a system control unit defines setpoint values for the sub-units and handles abnormal operating conditions. Here a fuzzy control system is proposed to accomplish these tasks. It means performing the standard power insertion into the line on the principle of maximum power tracking, preferable at a rather constant power input without flicker power, ensuring or improving line voltage quality with regard to reactive power and distortion power, or voltage waveform improvement, respectively. In addition, in case of a line interruption, the unit should be able to run independently from the line, establishing an insular power supply for the nearby customers and loads until the reconnection to the mains is done.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Interoperable technologies for automation Genetic algorithm approach for autonomous vehicles Development of a unified simulation methodology for electric networks using sliding modes Assist control for positioning task by flexible master-slave system Suppressing sensor lift-off effects on cracks signals in surface magnetic field measurement technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1