{"title":"用斜坡脉冲响应技术测量电容器内部电感","authors":"A. Yellaiah","doi":"10.1109/CEIDP.1993.378936","DOIUrl":null,"url":null,"abstract":"Experiments were carried out to measure the internal inductance of a capacitor by the ramp pulse method. It is demonstrated that the minimum width of the excitation pulse should be at least 10 times larger than the R/sub i/-C/sub t/ time constant. Care must be taken to minimize the extraneous signal pickup within the test circuit, and every lead must be as short as possible and shielded. It is also shown that suitable calibration should be carried out with noninductive resistors.<<ETX>>","PeriodicalId":149803,"journal":{"name":"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)","volume":"33 5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of internal inductance of capacitors by ramp pulse response technique\",\"authors\":\"A. Yellaiah\",\"doi\":\"10.1109/CEIDP.1993.378936\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Experiments were carried out to measure the internal inductance of a capacitor by the ramp pulse method. It is demonstrated that the minimum width of the excitation pulse should be at least 10 times larger than the R/sub i/-C/sub t/ time constant. Care must be taken to minimize the extraneous signal pickup within the test circuit, and every lead must be as short as possible and shielded. It is also shown that suitable calibration should be carried out with noninductive resistors.<<ETX>>\",\"PeriodicalId\":149803,\"journal\":{\"name\":\"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)\",\"volume\":\"33 5 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.1993.378936\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of IEEE Conference on Electrical Insulation and Dielectric Phenomena - (CEIDP '93)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1993.378936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
用斜脉冲法测量了电容器的内部电感。结果表明,激励脉冲的最小宽度应至少大于R/sub i/ c /sub t/时间常数的10倍。必须注意尽量减少测试电路内的外来信号拾取,并且每根引线必须尽可能短并屏蔽。还表明,应对无感电阻进行适当的校准
Measurement of internal inductance of capacitors by ramp pulse response technique
Experiments were carried out to measure the internal inductance of a capacitor by the ramp pulse method. It is demonstrated that the minimum width of the excitation pulse should be at least 10 times larger than the R/sub i/-C/sub t/ time constant. Care must be taken to minimize the extraneous signal pickup within the test circuit, and every lead must be as short as possible and shielded. It is also shown that suitable calibration should be carried out with noninductive resistors.<>