{"title":"荧光灯和led灯系统的性能分析","authors":"Debanka De, S. Sahana, B. Roy","doi":"10.1109/ICCECE.2016.8009572","DOIUrl":null,"url":null,"abstract":"This paper presents the performance analysis of different types of energy-efficient lamps used in indoor lighting applications. The objectives of this paper is to investigate and compare the electrical power quality and different photometrical parameters of few energy efficient lamps widely used in indoor applications now-a-days i.e. Fluorescent Tube Lights (FTLs), Compact Fluorescent Lamps (CFLs) and white Light Emitting Diodes (LEDs). These energy efficient lamps produce high total harmonic distortion but operate at high power factor. Few samples of commercial energy saving lamps are tested with different combinations of control gears and their performances are compared. The electrical and photometrical parameters are presented to verify the effectiveness of the lamp-ballast combinations. The result shows that although these lamps provide higher luminous efficacy, higher illumination but also high level of THD. The result also shows that the performance of these lamps do not change significantly with the change of normal commercial available control gears.","PeriodicalId":414303,"journal":{"name":"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)","volume":"94 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Performance analysis of fluorescent and led lamp system\",\"authors\":\"Debanka De, S. Sahana, B. Roy\",\"doi\":\"10.1109/ICCECE.2016.8009572\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the performance analysis of different types of energy-efficient lamps used in indoor lighting applications. The objectives of this paper is to investigate and compare the electrical power quality and different photometrical parameters of few energy efficient lamps widely used in indoor applications now-a-days i.e. Fluorescent Tube Lights (FTLs), Compact Fluorescent Lamps (CFLs) and white Light Emitting Diodes (LEDs). These energy efficient lamps produce high total harmonic distortion but operate at high power factor. Few samples of commercial energy saving lamps are tested with different combinations of control gears and their performances are compared. The electrical and photometrical parameters are presented to verify the effectiveness of the lamp-ballast combinations. The result shows that although these lamps provide higher luminous efficacy, higher illumination but also high level of THD. The result also shows that the performance of these lamps do not change significantly with the change of normal commercial available control gears.\",\"PeriodicalId\":414303,\"journal\":{\"name\":\"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)\",\"volume\":\"94 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCECE.2016.8009572\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Computer, Electrical & Communication Engineering (ICCECE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCECE.2016.8009572","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Performance analysis of fluorescent and led lamp system
This paper presents the performance analysis of different types of energy-efficient lamps used in indoor lighting applications. The objectives of this paper is to investigate and compare the electrical power quality and different photometrical parameters of few energy efficient lamps widely used in indoor applications now-a-days i.e. Fluorescent Tube Lights (FTLs), Compact Fluorescent Lamps (CFLs) and white Light Emitting Diodes (LEDs). These energy efficient lamps produce high total harmonic distortion but operate at high power factor. Few samples of commercial energy saving lamps are tested with different combinations of control gears and their performances are compared. The electrical and photometrical parameters are presented to verify the effectiveness of the lamp-ballast combinations. The result shows that although these lamps provide higher luminous efficacy, higher illumination but also high level of THD. The result also shows that the performance of these lamps do not change significantly with the change of normal commercial available control gears.