生物医学信号的速率自适应压缩感知与稀疏度方差

Vahid Behravan, Neil E. Glover, Rutger Farry, Patrick Chiang, M. Shoaib
{"title":"生物医学信号的速率自适应压缩感知与稀疏度方差","authors":"Vahid Behravan, Neil E. Glover, Rutger Farry, Patrick Chiang, M. Shoaib","doi":"10.1109/BSN.2015.7299419","DOIUrl":null,"url":null,"abstract":"Biomedical signals exhibit substantial variance in their sparsity, preventing conventional a-priori open-loop setting of the compressed sensing (CS) compression factor. In this work, we propose, analyze, and experimentally verify a rate-adaptive compressed-sensing system where the compression factor is modified automatically, based upon the sparsity of the input signal. Experimental results based on an embedded sensor platform exhibit a 16.2% improvement in power consumption for the proposed rate-adaptive CS versus traditional CS with a fixed compression factor. We also demonstrate the potential to improve this number to 24% through the use of an ultra low power processor in our embedded system.","PeriodicalId":447934,"journal":{"name":"2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","volume":"69 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"30","resultStr":"{\"title\":\"Rate-adaptive compressed-sensing and sparsity variance of biomedical signals\",\"authors\":\"Vahid Behravan, Neil E. Glover, Rutger Farry, Patrick Chiang, M. Shoaib\",\"doi\":\"10.1109/BSN.2015.7299419\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Biomedical signals exhibit substantial variance in their sparsity, preventing conventional a-priori open-loop setting of the compressed sensing (CS) compression factor. In this work, we propose, analyze, and experimentally verify a rate-adaptive compressed-sensing system where the compression factor is modified automatically, based upon the sparsity of the input signal. Experimental results based on an embedded sensor platform exhibit a 16.2% improvement in power consumption for the proposed rate-adaptive CS versus traditional CS with a fixed compression factor. We also demonstrate the potential to improve this number to 24% through the use of an ultra low power processor in our embedded system.\",\"PeriodicalId\":447934,\"journal\":{\"name\":\"2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN)\",\"volume\":\"69 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"30\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BSN.2015.7299419\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE 12th International Conference on Wearable and Implantable Body Sensor Networks (BSN)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BSN.2015.7299419","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 30

摘要

生物医学信号在其稀疏性上表现出实质性的差异,从而阻止了压缩感知(CS)压缩因子的传统先验开环设置。在这项工作中,我们提出、分析并实验验证了一种速率自适应压缩感知系统,该系统根据输入信号的稀疏性自动修改压缩因子。基于嵌入式传感器平台的实验结果表明,与具有固定压缩因子的传统CS相比,所提出的速率自适应CS的功耗提高了16.2%。我们还展示了通过在嵌入式系统中使用超低功耗处理器将这一数字提高到24%的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rate-adaptive compressed-sensing and sparsity variance of biomedical signals
Biomedical signals exhibit substantial variance in their sparsity, preventing conventional a-priori open-loop setting of the compressed sensing (CS) compression factor. In this work, we propose, analyze, and experimentally verify a rate-adaptive compressed-sensing system where the compression factor is modified automatically, based upon the sparsity of the input signal. Experimental results based on an embedded sensor platform exhibit a 16.2% improvement in power consumption for the proposed rate-adaptive CS versus traditional CS with a fixed compression factor. We also demonstrate the potential to improve this number to 24% through the use of an ultra low power processor in our embedded system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of a smart insole for ambulatory assessment of gait Anticipatory signals in kinematics and muscle activity during functional grasp and release Piezoelectrets and their applications as wearable physiological-signal sensors and energy harvesters Automated guidance from physiological sensing to reduce thermal-work strain levels on a novel task An unsupervised approach for gait-based authentication
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1