并网光伏系统和电动汽车充电站对电力变压器故障率行为的影响

Sebastián Torres, I. Durán, A. Marulanda, A. Pavas
{"title":"并网光伏系统和电动汽车充电站对电力变压器故障率行为的影响","authors":"Sebastián Torres, I. Durán, A. Marulanda, A. Pavas","doi":"10.1109/PEPQA.2019.8851532","DOIUrl":null,"url":null,"abstract":"This document presents the analysis of the failure rate of an oil-inmmersed header distribution transformer due to the presence of current harmonics produced by a Grid-Tied PV system and slow charging stations. Monte-Carlo simulations were performed to generate harmonic profiles in order to calculate the accelerated aging factor that along with the transformer health index determine the behavior of the transformer’s failure rate. The results show that harmonic distortion does not have a significant influence on the transformer life reduction, and that degradation of solid and liquid insulation is one of the cause of increase in the failure rate in long-term as they have a high relative weight in the health index.","PeriodicalId":192905,"journal":{"name":"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","volume":"232 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of Grid-Tied PV Systems and EV Charging Stations on Power Transformers Failure Rate Behaviour\",\"authors\":\"Sebastián Torres, I. Durán, A. Marulanda, A. Pavas\",\"doi\":\"10.1109/PEPQA.2019.8851532\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This document presents the analysis of the failure rate of an oil-inmmersed header distribution transformer due to the presence of current harmonics produced by a Grid-Tied PV system and slow charging stations. Monte-Carlo simulations were performed to generate harmonic profiles in order to calculate the accelerated aging factor that along with the transformer health index determine the behavior of the transformer’s failure rate. The results show that harmonic distortion does not have a significant influence on the transformer life reduction, and that degradation of solid and liquid insulation is one of the cause of increase in the failure rate in long-term as they have a high relative weight in the health index.\",\"PeriodicalId\":192905,\"journal\":{\"name\":\"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"volume\":\"232 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEPQA.2019.8851532\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Workshop on Power Electronics and Power Quality Applications (PEPQA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEPQA.2019.8851532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了由于并网光伏系统和慢速充电站产生的电流谐波而导致的油浸式集箱配电变压器故障率的分析。通过蒙特卡罗模拟生成谐波分布曲线,计算加速老化因子与变压器健康指数共同决定变压器故障率的行为。结果表明,谐波畸变对变压器寿命降低影响不显著,固体和液体绝缘在健康指数中占有较高的相对权重,其劣化是长期故障率上升的原因之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of Grid-Tied PV Systems and EV Charging Stations on Power Transformers Failure Rate Behaviour
This document presents the analysis of the failure rate of an oil-inmmersed header distribution transformer due to the presence of current harmonics produced by a Grid-Tied PV system and slow charging stations. Monte-Carlo simulations were performed to generate harmonic profiles in order to calculate the accelerated aging factor that along with the transformer health index determine the behavior of the transformer’s failure rate. The results show that harmonic distortion does not have a significant influence on the transformer life reduction, and that degradation of solid and liquid insulation is one of the cause of increase in the failure rate in long-term as they have a high relative weight in the health index.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A current controller for a grid-tied, cascade multilevel inverter Integration of Photovoltaic System in Low Voltage Electrical Network of the Electrical Engineering Building Experimental Magnetization Curve of a Transformer Considering Harmonic Distortion Evolving the Next Generation of Distribution Analysis Tools PMU and PDC server implementation integrated to real-time simulation tools
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1