利用充值控制方法进行自然采光节能实验研究

C. Wangkadilok, W. Sriratana, N. Tammarugwattana, L. Tanachaikhan
{"title":"利用充值控制方法进行自然采光节能实验研究","authors":"C. Wangkadilok, W. Sriratana, N. Tammarugwattana, L. Tanachaikhan","doi":"10.1109/SICE.2008.4655028","DOIUrl":null,"url":null,"abstract":"This paper presents the experiment-based analysis of interior illuminance from natural lighting through clear glazed window of a reference room located in Bangkok, Thailand, during February to May 2007 as a case study. The point illuminances measured by photoconductive sensors were collected every 5 minutes and the average interior illuminance from natural lighting were then calculated instantaneously. In this study, natural lighting also aims to reduce the requirement of electric lighting during daytime (7 am-5 pm) of the reference room. If natural lighting alone cannot supply the light at the required value, the electric lighting is assumed to be switched on under top-up control method to maintain the standard illuminance level. The average interior illuminance, which comprises of natural light and electric light, is controlled to be stable at the IES standard level of 500 lux. Nine sets of high performance lamp, 56 lm/W of efficacy, are assumed to supply the light to meet the standard condition. The requirements of supplementary lighting and possible savings during the test months are finally estimated.","PeriodicalId":152347,"journal":{"name":"2008 SICE Annual Conference","volume":"18 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"An experimental study of natural lighting for energy conservation using top-up control method\",\"authors\":\"C. Wangkadilok, W. Sriratana, N. Tammarugwattana, L. Tanachaikhan\",\"doi\":\"10.1109/SICE.2008.4655028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the experiment-based analysis of interior illuminance from natural lighting through clear glazed window of a reference room located in Bangkok, Thailand, during February to May 2007 as a case study. The point illuminances measured by photoconductive sensors were collected every 5 minutes and the average interior illuminance from natural lighting were then calculated instantaneously. In this study, natural lighting also aims to reduce the requirement of electric lighting during daytime (7 am-5 pm) of the reference room. If natural lighting alone cannot supply the light at the required value, the electric lighting is assumed to be switched on under top-up control method to maintain the standard illuminance level. The average interior illuminance, which comprises of natural light and electric light, is controlled to be stable at the IES standard level of 500 lux. Nine sets of high performance lamp, 56 lm/W of efficacy, are assumed to supply the light to meet the standard condition. The requirements of supplementary lighting and possible savings during the test months are finally estimated.\",\"PeriodicalId\":152347,\"journal\":{\"name\":\"2008 SICE Annual Conference\",\"volume\":\"18 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 SICE Annual Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SICE.2008.4655028\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 SICE Annual Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SICE.2008.4655028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文以2007年2月至5月泰国曼谷的一个资料室为例,对自然光通过透明玻璃窗照射的室内照度进行了实验分析。每隔5分钟采集光导传感器测得的点照度,并即时计算自然光的平均室内照度。在本研究中,自然采光也旨在减少参考室白天(上午7点至下午5点)对电力照明的需求。如果仅靠自然光无法提供所需的光值,则假定在补光控制方法下打开电灯,以保持标准照度水平。由自然光和电灯组成的平均室内照度被控制在500勒克斯的IES标准水平上。假设9组高性能灯,56 lm/W的效率,提供满足标准条件的光。最后估计了测试月份补充照明的需求和可能的节省。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
An experimental study of natural lighting for energy conservation using top-up control method
This paper presents the experiment-based analysis of interior illuminance from natural lighting through clear glazed window of a reference room located in Bangkok, Thailand, during February to May 2007 as a case study. The point illuminances measured by photoconductive sensors were collected every 5 minutes and the average interior illuminance from natural lighting were then calculated instantaneously. In this study, natural lighting also aims to reduce the requirement of electric lighting during daytime (7 am-5 pm) of the reference room. If natural lighting alone cannot supply the light at the required value, the electric lighting is assumed to be switched on under top-up control method to maintain the standard illuminance level. The average interior illuminance, which comprises of natural light and electric light, is controlled to be stable at the IES standard level of 500 lux. Nine sets of high performance lamp, 56 lm/W of efficacy, are assumed to supply the light to meet the standard condition. The requirements of supplementary lighting and possible savings during the test months are finally estimated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Construction of a Cr2C2-C peritectic point cell for thermocouple calibration Touch-pen interface with local environment map for mobile robot navigation Natural gradient actor-critic algorithms using random rectangular coarse coding Inverse additive perturbation-based optimization of robust PSS in an interconnected power system with wind farms Growing topological map for SLAM of mobile robots
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1