X. Qing, Zhi Ning Chen, T. See, C. K. Goh, T. M. Chiam
{"title":"射频在人体内/透过人体内的传输特性","authors":"X. Qing, Zhi Ning Chen, T. See, C. K. Goh, T. M. Chiam","doi":"10.1109/ICCIS.2010.5518586","DOIUrl":null,"url":null,"abstract":"In this paper, the RF transmission characteristics in/through human body are investigated experimentally and numerically. An experimental methodology to characterize the RF transmission of human body is presented. The proposed method addresses the challenge to characterize the RF transmission accurately and reliably without the body tissue effect on the antennas under test. The proposed methodology of using tissue-embedded antennas is validated at 403 MHz band (Medical Implant Communication Service, MICS).","PeriodicalId":445473,"journal":{"name":"2010 IEEE Conference on Cybernetics and Intelligent Systems","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"RF transmission characteristics in/through the human body\",\"authors\":\"X. Qing, Zhi Ning Chen, T. See, C. K. Goh, T. M. Chiam\",\"doi\":\"10.1109/ICCIS.2010.5518586\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, the RF transmission characteristics in/through human body are investigated experimentally and numerically. An experimental methodology to characterize the RF transmission of human body is presented. The proposed method addresses the challenge to characterize the RF transmission accurately and reliably without the body tissue effect on the antennas under test. The proposed methodology of using tissue-embedded antennas is validated at 403 MHz band (Medical Implant Communication Service, MICS).\",\"PeriodicalId\":445473,\"journal\":{\"name\":\"2010 IEEE Conference on Cybernetics and Intelligent Systems\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2010 IEEE Conference on Cybernetics and Intelligent Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCIS.2010.5518586\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE Conference on Cybernetics and Intelligent Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCIS.2010.5518586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
RF transmission characteristics in/through the human body
In this paper, the RF transmission characteristics in/through human body are investigated experimentally and numerically. An experimental methodology to characterize the RF transmission of human body is presented. The proposed method addresses the challenge to characterize the RF transmission accurately and reliably without the body tissue effect on the antennas under test. The proposed methodology of using tissue-embedded antennas is validated at 403 MHz band (Medical Implant Communication Service, MICS).