CHB逆变器异步电机故障后矢量控制

Manuchehr Fathi, M. Zolghadri, S. Ouni, Reza Babaloo
{"title":"CHB逆变器异步电机故障后矢量控制","authors":"Manuchehr Fathi, M. Zolghadri, S. Ouni, Reza Babaloo","doi":"10.1109/PEDSTC.2019.8697844","DOIUrl":null,"url":null,"abstract":"In this paper, a new post-fault vector control of an induction motor, fed by a faulty Cascaded H-Bridge (CHB) inverter, is presented. Among fault tolerant control methods, waveform based methods are suitable for closed-loop control and provide higher output voltage. In order to control the speed of the motor, a rotor field oriented control (RFOC) is used. During the fault, the FOC is modified to decrease the fault impact on the motor as low as possible. The proposed method is validated by means of simulation results for different loads and faults. The results show an improvement in both the final operating point and the transient response of the motor.","PeriodicalId":296229,"journal":{"name":"2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC)","volume":"4 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Post Fault Vector Control of an Induction Motor Fed by a CHB Inverter\",\"authors\":\"Manuchehr Fathi, M. Zolghadri, S. Ouni, Reza Babaloo\",\"doi\":\"10.1109/PEDSTC.2019.8697844\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a new post-fault vector control of an induction motor, fed by a faulty Cascaded H-Bridge (CHB) inverter, is presented. Among fault tolerant control methods, waveform based methods are suitable for closed-loop control and provide higher output voltage. In order to control the speed of the motor, a rotor field oriented control (RFOC) is used. During the fault, the FOC is modified to decrease the fault impact on the motor as low as possible. The proposed method is validated by means of simulation results for different loads and faults. The results show an improvement in both the final operating point and the transient response of the motor.\",\"PeriodicalId\":296229,\"journal\":{\"name\":\"2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC)\",\"volume\":\"4 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PEDSTC.2019.8697844\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PEDSTC.2019.8697844","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

本文提出了一种基于故障级联h桥(CHB)逆变器的异步电动机故障后矢量控制方法。在容错控制方法中,基于波形的方法适合于闭环控制,输出电压较高。为了控制电机的速度,采用了转子磁场定向控制(RFOC)。在故障期间,修改FOC以尽可能降低故障对电机的影响。通过不同负载和故障的仿真结果验证了该方法的有效性。结果表明,电机的最终工作点和瞬态响应都得到了改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Post Fault Vector Control of an Induction Motor Fed by a CHB Inverter
In this paper, a new post-fault vector control of an induction motor, fed by a faulty Cascaded H-Bridge (CHB) inverter, is presented. Among fault tolerant control methods, waveform based methods are suitable for closed-loop control and provide higher output voltage. In order to control the speed of the motor, a rotor field oriented control (RFOC) is used. During the fault, the FOC is modified to decrease the fault impact on the motor as low as possible. The proposed method is validated by means of simulation results for different loads and faults. The results show an improvement in both the final operating point and the transient response of the motor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stochastic Smart Charging of Electric Vehicles for Residential Homes with PV Integration Reducing Variation of Switching Frequency in Finite-State Predictive Torque of three-Phase Induction Motor Static Modeling of the IDC-PFC to Solve DC Power Flow Equations of MT-HVDC Grids Employing the Newton-Raphson Method State Estimation for Sensorless Control of BLDC Machine with Particle Filter Algorithm Deviation Control in Comparison with DTC and FOC for SynRM Drives
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1