基于时变卡尔曼滤波的角域内模控制

Perry Y. Li
{"title":"基于时变卡尔曼滤波的角域内模控制","authors":"Perry Y. Li","doi":"10.23919/ACC.2017.7963860","DOIUrl":null,"url":null,"abstract":"Angle-domain structured disturbances refer to disturbances that satisfy a dynamic structure in a generic angle variable which is monotonically increasing with time but not uniformly. A difficulty in designing controllers to compensate for such angle-domain structured disturbances is that the system is invariably either time-varying or angle-varying. This paper uses the affine parameterization control design perspective and proposes a straight forward design procedure that utilizes a time-varying Kalman filter to estimate the disturbance state and a feedforward controller to install the disturbance cancellation. A sandwiched system is assumed where the input and output plants can be non-minimum phase. With non-minimum phase input plants, approximate feedforward controls are proposed to avoid the need for full future information on the angular rate.","PeriodicalId":422926,"journal":{"name":"2017 American Control Conference (ACC)","volume":"67 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Angle-domain internal model control via a time-varying Kalman filter\",\"authors\":\"Perry Y. Li\",\"doi\":\"10.23919/ACC.2017.7963860\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Angle-domain structured disturbances refer to disturbances that satisfy a dynamic structure in a generic angle variable which is monotonically increasing with time but not uniformly. A difficulty in designing controllers to compensate for such angle-domain structured disturbances is that the system is invariably either time-varying or angle-varying. This paper uses the affine parameterization control design perspective and proposes a straight forward design procedure that utilizes a time-varying Kalman filter to estimate the disturbance state and a feedforward controller to install the disturbance cancellation. A sandwiched system is assumed where the input and output plants can be non-minimum phase. With non-minimum phase input plants, approximate feedforward controls are proposed to avoid the need for full future information on the angular rate.\",\"PeriodicalId\":422926,\"journal\":{\"name\":\"2017 American Control Conference (ACC)\",\"volume\":\"67 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-06-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2017 American Control Conference (ACC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23919/ACC.2017.7963860\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 American Control Conference (ACC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23919/ACC.2017.7963860","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

角域结构扰动是指在一个随时间单调增加但不均匀的一般角度变量中满足动态结构的扰动。设计控制器来补偿这种角域结构扰动的难点在于系统总是时变或角变的。本文从仿射参数化控制设计的角度出发,提出了一种直接的设计方法,即利用时变卡尔曼滤波器估计扰动状态,利用前馈控制器进行扰动抵消。假设一个夹层系统的输入和输出可以是非最小相位。对于非最小相位输入对象,提出了近似前馈控制,以避免对角速率的全部未来信息的需要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Angle-domain internal model control via a time-varying Kalman filter
Angle-domain structured disturbances refer to disturbances that satisfy a dynamic structure in a generic angle variable which is monotonically increasing with time but not uniformly. A difficulty in designing controllers to compensate for such angle-domain structured disturbances is that the system is invariably either time-varying or angle-varying. This paper uses the affine parameterization control design perspective and proposes a straight forward design procedure that utilizes a time-varying Kalman filter to estimate the disturbance state and a feedforward controller to install the disturbance cancellation. A sandwiched system is assumed where the input and output plants can be non-minimum phase. With non-minimum phase input plants, approximate feedforward controls are proposed to avoid the need for full future information on the angular rate.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Plenary and semi-plenary sessions Spatial Iterative Learning Control: Systems with input saturation Distributed Second Order Sliding Modes for Optimal Load Frequency Control Adaptive optimal observer design via approximate dynamic programming Nonlinear adaptive stabilization of a class of planar slow-fast systems at a non-hyperbolic point
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1