直接甲醇燃料电池的现状、挑战和前景

S. Narayanan, T. Valdez, A. Kindler, C. Witham, S. Surampudi, H. Frank
{"title":"直接甲醇燃料电池的现状、挑战和前景","authors":"S. Narayanan, T. Valdez, A. Kindler, C. Witham, S. Surampudi, H. Frank","doi":"10.1109/BCAA.2000.838360","DOIUrl":null,"url":null,"abstract":"The status of direct methanol fuel cell technology with respect to power density, efficiency and integrated system operation have been summarized. The key challenge in improving power density is combining with operation at low air flow rates in order to maintain a water balance, and achieve attractive system mass and size. Improved catalysts and membranes with low methanol permeability are key to achieving these improvements. Challenges relating to miniature DMFC for battery replacement are discussed. Possibilities of reduction in catalyst and membrane cost suggest that premium power applications (100 W-5 kW) could be an early point of entry for DMFC into commercial markets.","PeriodicalId":368992,"journal":{"name":"Fifteenth Annual Battery Conference on Applications and Advances (Cat. No.00TH8490)","volume":"45 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Direct methanol fuel cells-status, challenges and prospects\",\"authors\":\"S. Narayanan, T. Valdez, A. Kindler, C. Witham, S. Surampudi, H. Frank\",\"doi\":\"10.1109/BCAA.2000.838360\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The status of direct methanol fuel cell technology with respect to power density, efficiency and integrated system operation have been summarized. The key challenge in improving power density is combining with operation at low air flow rates in order to maintain a water balance, and achieve attractive system mass and size. Improved catalysts and membranes with low methanol permeability are key to achieving these improvements. Challenges relating to miniature DMFC for battery replacement are discussed. Possibilities of reduction in catalyst and membrane cost suggest that premium power applications (100 W-5 kW) could be an early point of entry for DMFC into commercial markets.\",\"PeriodicalId\":368992,\"journal\":{\"name\":\"Fifteenth Annual Battery Conference on Applications and Advances (Cat. No.00TH8490)\",\"volume\":\"45 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fifteenth Annual Battery Conference on Applications and Advances (Cat. No.00TH8490)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/BCAA.2000.838360\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fifteenth Annual Battery Conference on Applications and Advances (Cat. No.00TH8490)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BCAA.2000.838360","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

综述了直接甲醇燃料电池技术在功率密度、效率和综合系统运行等方面的研究现状。提高功率密度的关键挑战是与低空气流速下的运行相结合,以保持水平衡,并实现有吸引力的系统质量和尺寸。改进的催化剂和低甲醇渗透性的膜是实现这些改进的关键。讨论了用于电池更换的微型DMFC所面临的挑战。降低催化剂和膜成本的可能性表明,优质功率应用(100 W-5 kW)可能是DMFC进入商业市场的早期起点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Direct methanol fuel cells-status, challenges and prospects
The status of direct methanol fuel cell technology with respect to power density, efficiency and integrated system operation have been summarized. The key challenge in improving power density is combining with operation at low air flow rates in order to maintain a water balance, and achieve attractive system mass and size. Improved catalysts and membranes with low methanol permeability are key to achieving these improvements. Challenges relating to miniature DMFC for battery replacement are discussed. Possibilities of reduction in catalyst and membrane cost suggest that premium power applications (100 W-5 kW) could be an early point of entry for DMFC into commercial markets.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of VRLA separator saturation on EV battery life The Uncharted Territory-Thin Metal Film lead acid batteries A review of the melt blown process Health and safety aspects of fiber glass Battery pack state of charge estimator design using computational intelligence approaches
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1