{"title":"电静液执行器过载故障的检测","authors":"L. Márton, A. Varga","doi":"10.1109/MED.2011.5982990","DOIUrl":null,"url":null,"abstract":"This paper proposes a method for detecting faults generated by increased loads in a class of mechanical control systems. It is considered that the load (input disturbance) is unmeasurable, only its bounds corresponding to normal operation are known. To solve the fault detection problem, a detector was proposed for a class of linear control systems that can be implemented with low computational costs. The method is applicable for electro-hydrostatic actuators (EHA) with unknown load. The proposed fault detection approach is validated through simulations for jamming detection of aircraft control surfaces driven by EHA.","PeriodicalId":146203,"journal":{"name":"2011 19th Mediterranean Conference on Control & Automation (MED)","volume":"2 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Detection of overload generated faults in electro-hydrostatic actuators\",\"authors\":\"L. Márton, A. Varga\",\"doi\":\"10.1109/MED.2011.5982990\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a method for detecting faults generated by increased loads in a class of mechanical control systems. It is considered that the load (input disturbance) is unmeasurable, only its bounds corresponding to normal operation are known. To solve the fault detection problem, a detector was proposed for a class of linear control systems that can be implemented with low computational costs. The method is applicable for electro-hydrostatic actuators (EHA) with unknown load. The proposed fault detection approach is validated through simulations for jamming detection of aircraft control surfaces driven by EHA.\",\"PeriodicalId\":146203,\"journal\":{\"name\":\"2011 19th Mediterranean Conference on Control & Automation (MED)\",\"volume\":\"2 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 19th Mediterranean Conference on Control & Automation (MED)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MED.2011.5982990\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 19th Mediterranean Conference on Control & Automation (MED)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MED.2011.5982990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Detection of overload generated faults in electro-hydrostatic actuators
This paper proposes a method for detecting faults generated by increased loads in a class of mechanical control systems. It is considered that the load (input disturbance) is unmeasurable, only its bounds corresponding to normal operation are known. To solve the fault detection problem, a detector was proposed for a class of linear control systems that can be implemented with low computational costs. The method is applicable for electro-hydrostatic actuators (EHA) with unknown load. The proposed fault detection approach is validated through simulations for jamming detection of aircraft control surfaces driven by EHA.