F. Orsini, A. Scorza, A. Rossi, F. Botta, S. Sciuto, R. D. Giminiani
{"title":"一种用于生物反应研究的新型WBV平台上加速度和位移测量的初步不确定性分析","authors":"F. Orsini, A. Scorza, A. Rossi, F. Botta, S. Sciuto, R. D. Giminiani","doi":"10.1109/MeMeA.2016.7533722","DOIUrl":null,"url":null,"abstract":"Over the last decade, many studies have been conducted on the effects of mechanical vibration on the physical hormonal and neuromuscular responses of muscles: in some works the growth hormone response showed a dependence on the acceleration provided by Whole Body Vibration (WBV) platforms with respect to subjects responsiveness. Therefore the accuracy of acceleration measurements related to the excitation system is important and should be assessed. To this aim a preliminary study on the identification and evaluation of the measurement uncertainty sources in the measurement chain of a novel WBV platform developed by the Authors is here proposed. After the main measurement error sources have been identified, a Monte Carlo simulation Method has been implemented to obtain the uncertainty in accelerations and displacements provided by the WBV platform. Since main causes of uncertainty has been identified in the accelerometer sensitivity, its mounting and the data acquisition processing, Results of the test showed a relative uncertainty of about ±4% for acceleration and displacement measurements for frequencies between 20Hz and 60Hz.","PeriodicalId":221120,"journal":{"name":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","volume":"177 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"A preliminary uncertainty analysis of acceleration and displacement measurements on a novel WBV platform for biologic response studies\",\"authors\":\"F. Orsini, A. Scorza, A. Rossi, F. Botta, S. Sciuto, R. D. Giminiani\",\"doi\":\"10.1109/MeMeA.2016.7533722\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Over the last decade, many studies have been conducted on the effects of mechanical vibration on the physical hormonal and neuromuscular responses of muscles: in some works the growth hormone response showed a dependence on the acceleration provided by Whole Body Vibration (WBV) platforms with respect to subjects responsiveness. Therefore the accuracy of acceleration measurements related to the excitation system is important and should be assessed. To this aim a preliminary study on the identification and evaluation of the measurement uncertainty sources in the measurement chain of a novel WBV platform developed by the Authors is here proposed. After the main measurement error sources have been identified, a Monte Carlo simulation Method has been implemented to obtain the uncertainty in accelerations and displacements provided by the WBV platform. Since main causes of uncertainty has been identified in the accelerometer sensitivity, its mounting and the data acquisition processing, Results of the test showed a relative uncertainty of about ±4% for acceleration and displacement measurements for frequencies between 20Hz and 60Hz.\",\"PeriodicalId\":221120,\"journal\":{\"name\":\"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"volume\":\"177 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/MeMeA.2016.7533722\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MeMeA.2016.7533722","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A preliminary uncertainty analysis of acceleration and displacement measurements on a novel WBV platform for biologic response studies
Over the last decade, many studies have been conducted on the effects of mechanical vibration on the physical hormonal and neuromuscular responses of muscles: in some works the growth hormone response showed a dependence on the acceleration provided by Whole Body Vibration (WBV) platforms with respect to subjects responsiveness. Therefore the accuracy of acceleration measurements related to the excitation system is important and should be assessed. To this aim a preliminary study on the identification and evaluation of the measurement uncertainty sources in the measurement chain of a novel WBV platform developed by the Authors is here proposed. After the main measurement error sources have been identified, a Monte Carlo simulation Method has been implemented to obtain the uncertainty in accelerations and displacements provided by the WBV platform. Since main causes of uncertainty has been identified in the accelerometer sensitivity, its mounting and the data acquisition processing, Results of the test showed a relative uncertainty of about ±4% for acceleration and displacement measurements for frequencies between 20Hz and 60Hz.