{"title":"使用霍尔效应传感器的膝关节角计原型","authors":"M. L. B. Freitas, Wesley La Banca Freitas, S. Stevan Jr.","doi":"10.3895/JAIC.V7N1.12522","DOIUrl":null,"url":null,"abstract":"This work presents the development of a goniometer prototype to measure the knee joint angle. Three Hall effect sensors positioned at 120o to each other were used, together with a rectangular edge magnet positioned externally to these sensors. It was described the entire process of characterizing the sensors within the system, besides the structure of the goniometer. As a result, angles were measured from 0o to 140o, with a maximum measurement error of 1.015o. Finally, it was concluded that the prototype made it possible to measure the angles at the proposed values, in addition to bringing several proposals for system improvements for future work, such as the positioning of the sensors, improving the angle validation structure, among others.","PeriodicalId":346963,"journal":{"name":"Journal of Applied Instrumentation and Control","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Knee Joint Goniometer Prototype using Hall Effect Sensors\",\"authors\":\"M. L. B. Freitas, Wesley La Banca Freitas, S. Stevan Jr.\",\"doi\":\"10.3895/JAIC.V7N1.12522\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This work presents the development of a goniometer prototype to measure the knee joint angle. Three Hall effect sensors positioned at 120o to each other were used, together with a rectangular edge magnet positioned externally to these sensors. It was described the entire process of characterizing the sensors within the system, besides the structure of the goniometer. As a result, angles were measured from 0o to 140o, with a maximum measurement error of 1.015o. Finally, it was concluded that the prototype made it possible to measure the angles at the proposed values, in addition to bringing several proposals for system improvements for future work, such as the positioning of the sensors, improving the angle validation structure, among others.\",\"PeriodicalId\":346963,\"journal\":{\"name\":\"Journal of Applied Instrumentation and Control\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-10-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Instrumentation and Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3895/JAIC.V7N1.12522\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Instrumentation and Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3895/JAIC.V7N1.12522","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

这项工作提出了一个测量膝关节角度的测角仪原型的发展。三个霍尔效应传感器彼此定位在1200度,再加上一个矩形边缘磁铁定位在这些传感器的外部。除了介绍测角仪的结构外,还介绍了系统内传感器的整个表征过程。因此,角度测量范围为0 ~ 140°,最大测量误差为1.015°。最后,得出的结论是,该原型使得在建议值下测量角度成为可能,此外还为未来的工作提出了一些系统改进建议,例如传感器的定位,改进角度验证结构等。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Knee Joint Goniometer Prototype using Hall Effect Sensors
This work presents the development of a goniometer prototype to measure the knee joint angle. Three Hall effect sensors positioned at 120o to each other were used, together with a rectangular edge magnet positioned externally to these sensors. It was described the entire process of characterizing the sensors within the system, besides the structure of the goniometer. As a result, angles were measured from 0o to 140o, with a maximum measurement error of 1.015o. Finally, it was concluded that the prototype made it possible to measure the angles at the proposed values, in addition to bringing several proposals for system improvements for future work, such as the positioning of the sensors, improving the angle validation structure, among others.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Um Sistema de Controle Utilizando Algoritmo NAP Aplicado a uma Unidade Experimental no Controle de Vazão On the Applicability of Behavior Driven Development for Automotive Software Testing at the Functional Model Level Electricity consumption meter for the White Tariff and feasibility study of tariff migration to residence Regulatory Control of Mass Flowrate in an Ore Feeding System with Time-Delayed Gain-Variant Dynamics A Incerteza ao Detectar Falha de Barra Quebrada em Baixo, Médio e Nominal Escorregamento
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1