用电流最小法求解非正弦条件下的最优无功补偿

U. Mujumdar, J. Joshi
{"title":"用电流最小法求解非正弦条件下的最优无功补偿","authors":"U. Mujumdar, J. Joshi","doi":"10.1109/ICPES.2011.6156649","DOIUrl":null,"url":null,"abstract":"For systems with non sinusoidal voltage and current, reactive power calculation using conventional power triangle method is the summation of displacement and distortion reactive power. Under such condition, attempt to make power factor unity, using shunt compensator, overcompensates the system and excess capacitor effectively increases the system current which is not desirable. In this paper, a new method for reactive power compensation using passive components is presented. The proposed approach is based on current minimization and does not need any reactive power definition for compensation. Reactive power demand of the load is calculated in terms of desired shunt capacitor current, using addition of test capacitor in the system. Capacitive current required to minimize the circuit current is calculated from the measured values of change in circuit current and test capacitor current. Mathematical equations are developed for the computation of compensation capacitor under sinusoidal as well as non sinusoidal conditions. The method has been validated by testing under various load conditions with an experimental prototype developed using 8 bit microcontroller ATMega32.","PeriodicalId":158903,"journal":{"name":"2011 International Conference on Power and Energy Systems","volume":"8 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Optimal reactive power compensation under non sinusoidal conditions using current minimization method\",\"authors\":\"U. Mujumdar, J. Joshi\",\"doi\":\"10.1109/ICPES.2011.6156649\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"For systems with non sinusoidal voltage and current, reactive power calculation using conventional power triangle method is the summation of displacement and distortion reactive power. Under such condition, attempt to make power factor unity, using shunt compensator, overcompensates the system and excess capacitor effectively increases the system current which is not desirable. In this paper, a new method for reactive power compensation using passive components is presented. The proposed approach is based on current minimization and does not need any reactive power definition for compensation. Reactive power demand of the load is calculated in terms of desired shunt capacitor current, using addition of test capacitor in the system. Capacitive current required to minimize the circuit current is calculated from the measured values of change in circuit current and test capacitor current. Mathematical equations are developed for the computation of compensation capacitor under sinusoidal as well as non sinusoidal conditions. The method has been validated by testing under various load conditions with an experimental prototype developed using 8 bit microcontroller ATMega32.\",\"PeriodicalId\":158903,\"journal\":{\"name\":\"2011 International Conference on Power and Energy Systems\",\"volume\":\"8 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Power and Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPES.2011.6156649\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Power and Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPES.2011.6156649","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

对于电压电流非正弦的系统,采用传统的功率三角法计算无功功率是位移和畸变无功功率之和。在这种情况下,试图使功率因数统一,采用并联补偿器,对系统进行过补偿,过量的电容有效地增加了系统电流,这是不可取的。本文提出了一种利用无源元件进行无功补偿的新方法。该方法基于电流最小化,不需要任何无功功率定义进行补偿。负载的无功功率需求是通过在系统中添加测试电容器,以期望并联电容器电流来计算的。使电路电流最小所需的容性电流是根据电路电流和测试电容器电流的变化的测量值计算出来的。建立了补偿电容在正弦和非正弦条件下的计算公式。该方法已通过使用8位微控制器ATMega32开发的实验样机在各种负载条件下进行测试验证。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimal reactive power compensation under non sinusoidal conditions using current minimization method
For systems with non sinusoidal voltage and current, reactive power calculation using conventional power triangle method is the summation of displacement and distortion reactive power. Under such condition, attempt to make power factor unity, using shunt compensator, overcompensates the system and excess capacitor effectively increases the system current which is not desirable. In this paper, a new method for reactive power compensation using passive components is presented. The proposed approach is based on current minimization and does not need any reactive power definition for compensation. Reactive power demand of the load is calculated in terms of desired shunt capacitor current, using addition of test capacitor in the system. Capacitive current required to minimize the circuit current is calculated from the measured values of change in circuit current and test capacitor current. Mathematical equations are developed for the computation of compensation capacitor under sinusoidal as well as non sinusoidal conditions. The method has been validated by testing under various load conditions with an experimental prototype developed using 8 bit microcontroller ATMega32.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On the optimal tuning of FACTS based stabilizers for dynamic stability enhancement in multimachine power systems A new proposal for voltage regulation multi feeders/Multibus systems using MC-DVR Deployment of System Protection Schemes for enhancing reliability of power system: Operational experience of wide area SPS in Northern Regional Power System in India Power quality improvement in DTC based induction motor drive using Minnesota rectifier Neural learning algorithm based power quality enhancement for three phase three wire distribution system utilizing shunt active power filter strategy
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1