{"title":"服装集成可穿戴传感中的服装定位与漂移","authors":"Guido Gioberto, Lucy E. Dunne","doi":"10.1109/ISWC.2012.35","DOIUrl":null,"url":null,"abstract":"Perceptibility on the part of the user is a key influence on the success or failure of a wearable sensor. Most wearable sensors seek to measure or monitor parameters of the body as accurately as possible, yet wearable sensors are notoriously plagued by the error (also referred as noise) that may be introduced by the movement of the sensor over the body surface. In this paper, we implement a novel method for analyzing error introduced by garment properties in garment-integrated wearable sensing during body movement, and assess in detail the errors introduced by donning and doffing of a garment (garment positioning error) and by garment drift during the gait cycle (drift error).","PeriodicalId":190627,"journal":{"name":"2012 16th International Symposium on Wearable Computers","volume":"13 6","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Garment Positioning and Drift in Garment-Integrated Wearable Sensing\",\"authors\":\"Guido Gioberto, Lucy E. Dunne\",\"doi\":\"10.1109/ISWC.2012.35\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Perceptibility on the part of the user is a key influence on the success or failure of a wearable sensor. Most wearable sensors seek to measure or monitor parameters of the body as accurately as possible, yet wearable sensors are notoriously plagued by the error (also referred as noise) that may be introduced by the movement of the sensor over the body surface. In this paper, we implement a novel method for analyzing error introduced by garment properties in garment-integrated wearable sensing during body movement, and assess in detail the errors introduced by donning and doffing of a garment (garment positioning error) and by garment drift during the gait cycle (drift error).\",\"PeriodicalId\":190627,\"journal\":{\"name\":\"2012 16th International Symposium on Wearable Computers\",\"volume\":\"13 6\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 16th International Symposium on Wearable Computers\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISWC.2012.35\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 16th International Symposium on Wearable Computers","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISWC.2012.35","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Garment Positioning and Drift in Garment-Integrated Wearable Sensing
Perceptibility on the part of the user is a key influence on the success or failure of a wearable sensor. Most wearable sensors seek to measure or monitor parameters of the body as accurately as possible, yet wearable sensors are notoriously plagued by the error (also referred as noise) that may be introduced by the movement of the sensor over the body surface. In this paper, we implement a novel method for analyzing error introduced by garment properties in garment-integrated wearable sensing during body movement, and assess in detail the errors introduced by donning and doffing of a garment (garment positioning error) and by garment drift during the gait cycle (drift error).