{"title":"ANALISIS ACTIVE FIRE PROTECTION SYSTEM APAR DAN HIDRAN DI AREA OG FIELD PT. XYZ TAHUN 2022","authors":"Husen Husen, Y. Yunita, S. Sahuri, Faris Siddique","doi":"10.51544/jkmlh.v7i1.3103","DOIUrl":null,"url":null,"abstract":"Fires have a very broad hazard impact, which includes social and economic impacts, so it is necessary to be prepared to deal with fires. The existence of an active fire protection system is one form of effort for early prevention and mitigation of potential fire hazards. The purpose of this study was to determine the suitability of the inspection program, inspection procedures and implementation or application of fire extinguishers and hydrants in the OG Field area of PT. XYZ with PerMenNaKerTrans No. 4 of 1980, SNI-03-1745-2000, NFPA 10 of 2013 and NFPA 25 of 2014. The type and research design used is a qualitative method, with a descriptive research design using a comparative approach. The population in this study were all workers in the OG Field area of PT. XYZ with a number of workers as many as 248 people, then it is determined 20 informants including 2 key informants. Data collection techniques through direct observation or survey in the OG Field area of PT. XYZ and conduct interviews. Based on the results of observations and interviews that the author has done, the area of OG Field PT. XYZ already has an inspection program, inspection procedures and implementation or application of fire extinguishers and hydrants in accordance with PerMenNaKerTrans No. 4 of 1980, SNI-03-1745-2000, NFPA 10 of 2013 and NFPA 25 of 2014. However, there are still discrepancies in the hydrotest or hydrostatic testing of the fire extinguisher tube, instructions for use or operation of the fire extinguisher, placement of the fire extinguisher and damage or defects in the hydrant.","PeriodicalId":186380,"journal":{"name":"JURNAL KESEHATAN MASYARAKAT DAN LINGKUNGAN HIDUP","volume":"214 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JURNAL KESEHATAN MASYARAKAT DAN LINGKUNGAN HIDUP","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51544/jkmlh.v7i1.3103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

火灾具有非常广泛的危害影响,其中包括社会和经济影响,因此有必要做好应对火灾的准备。主动消防系统的存在是早期预防和减轻潜在火灾危险的一种努力形式。本研究的目的是根据1980年PerMenNaKerTrans No. 4, sn -03-1745-2000, 2013年NFPA 10和2014年NFPA 25,确定PT. XYZ OG Field区域灭火器和消火栓的检验计划、检验程序和实施或应用的适用性。使用的类型和研究设计是一种定性方法,使用比较方法的描述性研究设计。本研究人群均为XYZ PT. OG Field区域的工人,工人人数达248人,则确定20名告密者,其中2名是关键告密者。数据收集技术,通过直接观察或调查在PT. XYZ的OG领域,并进行访谈。根据笔者所做的观察和访谈的结果,OG Field PT. XYZ区域已经根据1980年PerMenNaKerTrans No. 4、sn -03-1745-2000、2013年NFPA 10和2014年NFPA 25的要求,制定了灭火器和消火栓的检查计划、检查程序和实施或应用。但是,在灭火器管的水压试验或水压试验、灭火器的使用或操作说明、灭火器的放置和消火栓的损坏或缺陷等方面仍然存在差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ANALISIS ACTIVE FIRE PROTECTION SYSTEM APAR DAN HIDRAN DI AREA OG FIELD PT. XYZ TAHUN 2022
Fires have a very broad hazard impact, which includes social and economic impacts, so it is necessary to be prepared to deal with fires. The existence of an active fire protection system is one form of effort for early prevention and mitigation of potential fire hazards. The purpose of this study was to determine the suitability of the inspection program, inspection procedures and implementation or application of fire extinguishers and hydrants in the OG Field area of PT. XYZ with PerMenNaKerTrans No. 4 of 1980, SNI-03-1745-2000, NFPA 10 of 2013 and NFPA 25 of 2014. The type and research design used is a qualitative method, with a descriptive research design using a comparative approach. The population in this study were all workers in the OG Field area of PT. XYZ with a number of workers as many as 248 people, then it is determined 20 informants including 2 key informants. Data collection techniques through direct observation or survey in the OG Field area of PT. XYZ and conduct interviews. Based on the results of observations and interviews that the author has done, the area of OG Field PT. XYZ already has an inspection program, inspection procedures and implementation or application of fire extinguishers and hydrants in accordance with PerMenNaKerTrans No. 4 of 1980, SNI-03-1745-2000, NFPA 10 of 2013 and NFPA 25 of 2014. However, there are still discrepancies in the hydrotest or hydrostatic testing of the fire extinguisher tube, instructions for use or operation of the fire extinguisher, placement of the fire extinguisher and damage or defects in the hydrant.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
HUBUNGAN DUKUNGAN KELUARGA DALAM PEMBERIAN ASI EKSKLUSIF DENGAN KEJADIAN STUNTING BALITA UMUR 24-59 BULAN DI WILAYAH KERJA PUSKESMAS SUMBANG II PENGETAHUAN IBU DALAM PENCEGAHAN STUNTING PADA ANAK USIA PRA SEKOLAH DI BPM MARIANA PENGARUH EDUKASI MEDIA VIDIO ANIMASI TENTANG ASI EKSKLUSIF TERHADAP SIKAP IBU DI WILAYAH PUSKESMAS LIMBONG TAHUN 2023 PENGARUH METODE SIMULASI DAN DEMONSTRASI TERHADAP KEMAMPUAN MENYIKAT GIGI PADA SISWA SDN GUE GAJAH ACEH BESAR PEMANTAUAN KUALITAS AIR SUNGAI CILEUNGSI SECARA ONLINE MELALUI WEBSITE ONLINE MONITORING
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1